Malfunction remedy
Malfunction
Pumps do not start
Unit does not respond to hand-
held transmitter
Insufficient fountain height
Unit switches off after a brief run-
ning time (approx. 10 s)
Technical data
Switching power pack
Primary
Secondary
Protection type
Protection class
Ambient temperature
Dimensions (L × W × H)
Weight
Cause
No mains voltage
Hand-held transmitter not regis-
tered
Impeller unit blocked or soiled
Pump strainer casing soiled
Nozzles soiled
Water temperature too high
Pumps run dry
Power supply voltage
Mains frequency
Max. power consumption
Cable length
Output voltage
Max. output current
Cable length
Remedy
Check the mains voltage.
Check supply lines.
Register hand-held transmitter
Clean the impeller unit
Clean strainer casing
Clean nozzles
Note maximum water temperature
of + 35°C. For switching on again,
pull the power plug and reinsert in
the socket.
Check water level and, if necessary,
top up the water. For switching on
again, pull the power plug and rein-
sert in the socket.
100 VA / 12 V DC
V AC
220 ... 240
HZ
50/60
W
110
m
2.0
V DC
12
A
8.5
m
0.5
IP44
II
°C
-10 ... +35
mm
231 × 148 × 68
kg
2.3
EN
31