ASSEMBLY
Rotate the miter table until the blade is parallel with the
framing square.
Push the miter lock lever down to lock the miter table.
Press the miter detent bypass until it clicks. Release to
engage the detent function.
Rotate the miter scale to the 0
or until the detent engages in the detent plate.
UNLOCKED
(DETENT
ENGAGED)
UNLOCKED
(DETENT
DISENGAGED)
SLIDING
MITER
FENCE
VIEW OF BLADE NOT SQUARE WITH FENCE,
ADJUSTMENTS ARE REQUIRED
°
position on the miter scale
LOCKED
Fig. 22
BLADE
FRAMING
MITER
SQUARE
TABLE
Fig. 23
Tighten the 4 visible screws that secure the miter scale/
detent plate.
Lift the miter lock lever to unlock the miter table.
Press the miter detent bypass button until it clicks, then
rotate the miter table to the 15
scale.
Tighten the remaining screw to secure the miter scale/
detent plate.
SLIDING
MITER
FENCE
VIEW OF BLADE NOT SQUARE WITH FENCE,
ADJUSTMENTS ARE REQUIRED
MITER
SCALE
21 - English
°
position on the miter
BLADE
FRAMING
MITER
SQUARE
TABLE
Fig. 24
SCALE
INDICATOR
Fig. 25