• If an error code appears on the display, refer to the table:
Trouble code
Possible reasons
No pot/pan on the plate;
Non usable pans on the plate;
E0
Diameter of pot is smaller
IGBT Electrocircuit mulfunction.
E1
IGBT sensors is in open circuit or in short circuit.
Temperature sensor failure
E2
E3
Low voltage (<90 V)
E4
Overvoltage 270 V
E5
Open circuit circuit top sensor/ short circuit
E6
Overheating of the plate.
MAINTENANCE AND CLEANING
• Before you proceed to cleaning, unplug the appliance from the mains and wait until the plate is totally cold.
• You can clean the body with a slightly dampened cloth.
• To clean the plate it is enough to use a slightly dampened cloth with soap. You also can clean the plate with
special products to clean vitro ceramic plates.
• If there are some hard residues you can use a scraper suitable for vitro ceramic hobs.
• Do not use abrasive or chemical products, metallic scourers, and such may deteriorate the surfaces.
ENVIRONMENT PROTECTION
• Dispose the appliance according to the local garbage regulations.
• Never throw it away to the rubbish. So you will help to the improvement of the environment.
ATTENTION
• Lisez attentivement ces instructions avant de mettre
l'appareil en fonctionnement et conservez-les pour de futures
consultations.
• Cet appareil peut être utilisé par les enfants de plus de 8
ans et les personnes handicapées physiques, sensorielles ou
mentales réduites ou sans expérience ni connaissance, si elles
Solutions
Use proper suitable cooking
utensils
Please contact the supplier or
go to a qualified service center.
Please contact the supplier or
go to a qualified service center.
Check the power supply and
wait for it to return to normal.
Check the power supply and
wait for it to return to normal.
Contact a Technical Service.
Wait a few minutes until it cools
down.