6. Connection example of 1 door
Electromagnetic Lock 12 V/600 mA max
Adjust the output to 14.2 V DC,
using screwdriver
See user manual
12 V battery
This product herewith complies with the requirements of the EMC directive 2014/30/EU.
In addition, it complies with RoHS2 directive EN50581:2012 and RoHS3 Directive 2015/863/EU.
1
2
Diode
1N4001
Door contact
Push button
Dip Switch
OFF
ON
Lan
Autonomous
Master
Slave
Run LED
Reader
- For doors equipped with 2 readers, one must be at address 0 and the other at address 1. If there is
only 1 reader, then it is recommended to be put with address 0.
- LIYCY cable, twisted pair, up to 80 m (5) If more than 80 m are needed, then termination resis-
tors (120 ohm) may be required at both ends of the RS-485 line, while taking into consideration the
Address 0
lengths proposed on our web site.
- Alarm cable 2x0,22. (6)
- The cross section of the cable depends on the current needed by the lock. (7)
Note: The elevators relay boards (WS4-RB-12) are connected on the same RS-485 lines as the readers.