INSUlATING JACKeT ReQUIReMeNTS
• If your cabinet/ structure has external or internal combustible
components (wood, plastic, etc�) your griddle MUST use an insu-
lating jacket�
• If installed under overhead combustible construction, the appliance
MUST be installed in conjunction with a suitable Ul710 or UlC S646
approved heavy duty vent hood only�
NO combustibles in this area
Combustibles OKAY in this area
WITH JACKET
Cabinet/ structure can be made
with combustibles (Wood, plastic
(PVC, HdPe), oil-based paint,
lacquer, etc�)
NOTICE
The insulating jacket must
be permanently secured to
the cabinet.
do NoT operate this appliance any closer than 6 in (150 mm) from
the sides and back of the appliance to vertical combustible construc-
tion� (walls/ backsplash)
A A
A
A
WITH JACKET
A A
A A
A A
A = 6 in (150 mm)
A = 6 in (150 mm)
BUIlT-IN INSTAllATIoN
B B
A A
F F
d
d
e e
C C
The cabinet CAN NOT store 2 or more gas cylinders.
BLACKSTONEPRODUCTS.COM/SUPPORT
Insulating Jacket
Insulating Jacket
CAVITY MINIMUM DIMENSIONS
A: A: Width = 45.75 in (117 cm)
Width = 45.75 in (117 cm)
B: B: depth = 27.5 in (70 cm)
depth = 27.5 in (70 cm)
C: C: Height = 8 in (21 cm)
Height = 8 in (21 cm)
(>8 in will cause hood interference)
(>8 in will cause hood interference)
HOLE MINIMUM DIMENSIONS
D: D: distance from side = 10.5 in (27 cm)
distance from side = 10.5 in (27 cm)
E: E: distance from front = 3.75 in
distance from front = 3.75 in
(10 cm)
(10 cm)
F: F: diameter = 4.5 in (12 cm)
diameter = 4.5 in (12 cm)
WARNING
USING YOUR BLACKSTONE
NO JACKET
Cabinet/ structure MUST be
made with NoN-combustibles
oNlY (Brick, stone, cement,
metal, glass, etc�)
do NoT operate this appliance any closer than 36 in (1 m) from the
sides and back of the appliance to combustible construction�
A
A
A A
NO JACKET
A A
A A
A A
A = 36 in (150 mm)
A = 36 in (150 mm)
LPG CYLINDER ENCLOSURE
CONSTRUCTION
A: A: 4x6 in (10x15 cm) vents at bottom,
4x6 in (10x15 cm) vents at bottom,
and both sides of cabinet.
and both sides of cabinet.
B: B: Plenum wall to separate the lPG
Plenum wall to separate the lPG
cylinder compartment.
cylinder compartment.
C: C: lPG cylinder access door.
lPG cylinder access door.
B B
C C
A
A
| OWNER'S MANUAL
NATURAL GAS ENCLOSURE
CONSTRUCTION
A: A: 4x6 in (10x15 cm) vents at top, and
4x6 in (10x15 cm) vents at top, and
both sides of cabinet.
both sides of cabinet.
A A
A A
A A
09

Publicidad