The device must be installed inside an electric panel or cabinet.
CONNECTION OF THE POWER SUPPLY UNIT
DESCRIPTION OF THE TERMINALS
N, L
Input voltage 110-230V~
}
V-
Output voltage for video door phone
V+
TECHNICAL DATA
Power supply: ................................................................................................................ 100-240 V~ 50-60 Hz
Power: ............................................................................................................................................max. 11 W
Secondary output: ................................................................................................................. 24 V
Power dissipated after after 1 hour of functioning: ........................................................Max 11 Wh (~40 KJ)
Dimensions (WxDxH): ................................................................................36 (2 DIN modules) x 98 x 60 mm
DS1722-086A
Installation on DIN bar (2 x 18 mm modules)
V- V- V+ V+
Power supply
110-230V~
1
2
To the video door phone
NC NC N L
0,42 A
3