O P E R A T I N G I N S T R U C T I O N S | WTT12-S
Height above sea level dur‐
ing operation
EMC
Shock resistance
Vibration resistance
Vibration
Ambient light suppression
1)
At or above T
= 45 °C, a max. load current of I
a
20
(0.79)
1
2
7
M12x1
Figure: Dimensional drawing WTT12-S
Center of optical axis, sender
1
Center of optical axis, receiver
2
Mounting hole D4.2 mm
6
Male connector, M12, 5-pin
7
You can obtain declarations of conformity, certificates, and the current operating
instructions for the product at www.sick.com. To do so, enter the product part number
in the search field (part number: see the entry in the "P/N" or "Ident. no." field on the
type label).
SICK uses open source software which is published by the rights holders under a
free license. Among others, the following license types are used: GNU General Public
License (GPL version 2, GPL version 3), GNU Lesser General Public License (LGPL), MIT
license, zlib license and licenses derived from the BSD license.
This program is provided for general use without warranty of any kind. This warranty
disclaimer also extends to the implicit assurance of marketability or suitability of the
program for a particular purpose.
WTT12-S
< 3,000 m
•
EN 60947-5-3:2013
•
EN 61000-6-7:2015
Single shock: 30 g / 11 ms (3 positive, 3 negative shocks along
the X, Y and Z axes) (EN 60068-2-27)
Continuous shock: 25 g / 6 ms (1,000 positive, 1,000 negative
shocks along the X, Y and Z axes) (EN 60068-2-27)
20 Hz - 1,000 Hz, 1 g / axis, 1 octave/min (EN 60068-2-6)
20 Hz - 2,000 Hz, 10 g RMS/axis (EN 60068-2-64)
50 kLux
= 50 mA is permissible.
max
44.2
(1.74)
31.9
(1.26)
6
(0.24)
6
4
(0.16)
36.5
(1.44)
8029123/2024/01/15 | SICK
Subject to change without notice