In order to minimize energy usage when airing
the room by opening the windows, it is advisable
to switch off the unit.
1.4 Servicing
Do not use abrasive or aggressive cleansers to
clean the heater.
Use a vacuum cleaner regularly to clean the
upper and lower air grids.
2. Installation instructions
Attention!
The installation, electrical connection and first
operation of this appliance should be carried
out by a qualified installer.
The company does not accept liability for
failure of any goods supplied which have not
been installed and operated in accordance with
the manufacturer's instructions.
This convector heater must be installed by an
authorised serviceman in conjunction with these
instructions.
These installation instructions belong to the
heater and must be handed on to the successor
if the heater is sold.
Stiebel Eltron convector heaters are direct
electric heaters designed to be mounted on the
wall and are particularly suitable for heating
smaller rooms such as utility rooms, kitchen, bath-
and washrooms etc.
The convector heater is supplied with a lead.
The convector heater must not be mounted
immediately below a wall socket.
Type
Connecting power
Breadth
Heigth
Depth
with wall mounting
Measure A
6
CNS
CNS
50
75
W
500
750
mm
370
370
mm
450
450
mm
80
80
100
100
121
121
for the professional
During the just operation, the heater
may give off a smell. Ensure that the
room is ventilated (for example, open a
window).
2.1 Attaching the wall mounting bra-
cket
The wall mounting bracket is oriented centrally
(see figure and the following table).
Use the wall-mounting bracket as a template for
positioning the heater correctly and providing the
correct distance from the floor.
Place the bracket on the floor. Mark the screw-
holes through the drill holes (1).
CNS
CNS
CNS
100
125
150
1000
1250
1500
440
520
590
450
450
450
80
80
100
100
100
195
269
343
CNS
CNS
175
200
1750
2000
665
740
450
450
80
80
80
100
100
417
491
CNS
250
2500
890
450
80
100
639