PREPARATION
OF AIR CONDITIONER
CHASSIS
PREPARACION
DEL CHASIS DEL
ACONDICIONADOR
DE AIRE
It is much easier and also safer to install an empty cabinet in a window and we suggest you to
do
so.
NOTE: Do not remove any internal styrofoam from the unit, it is part of air guider.
Do not pull on STYROFOAM AIR GUIDER as damage may occur.
1. Remove the air conditioner
from carton•
2. Remove 2 screws from rear side of cabinet•
3. Remove the chassis locking bracket and save for later use.
4. Remove the chassis grounding
screw and save for later use.
5. Slide out the chassis from the cabinet by pulling on the chassis grip.
Es mucho m_s f6cil y tambien seguro instalar la caja vacia en la ventana y le sugerimos que
asi Io haga.
NOTA: No remueva ninguna espuma poliestir_nica
del interior de la unidad, esta forma parte
de la gula de aire.
No tire de la GUJA DE AIRE DE ESTIROESPUMA pues puede da_arla.
1. Retire el acondicionador
de aire de su envoltura.
2. Retire los dos torniJlos del lado posterior de la caja.
3. Retire los m_nsulas de retenci6n del chasis y gu6rdelas
para usa posterior.
4. Retire el tornillo de puesta a tierra del chasis y guardelo
para usa posterior.
5. Deslice hocia afuera el chasis de la caia tirando del asidero del chasis.
dd chasis
Evaporator coil
Serpentin
evaporador
\
• Cabinet
Caia
Condensercoil
Serpenfin condensador
Base del chos_s
Bulkhead Separates indoor ,fromoutdoor side
RefiJerzo (Separa el interior de exterior}
Grip
Grounding
Power cord
Grip
wire location
Cable de atimentaci6n
Cable de
atimentaci6n