Operating instructions SATAjet 3000 K (RP/HVLP)
Should the material connection 93526 in the spray gun body loosen when removing
the material tube 92031, respectively, please proceed as follows:
•
Remove material connection 93526 completely
•
Pull out the insert 93559 from the spray gun via the paint nozzle and remove paint
nozzle
•
Plug in insert 93559 aligned with drilling for the material connection
•
Seal material connection with Loctite 638 and install, required locking torque
40-45 Nm
A mounting instruction of the air distribution ring can be found as a PDF and as a
video on our homepage www.sata.com/Media. Also more information on spray gun
cleaning can be obtained from a video.
Important Notice:
Gun may be cleaned with solvent or cleaning agents manually or in a conventional gun
washing machine.
The following actions damage the gun/system, may lead to the loss of the
explosion-proofness approval and entirely annull any warranty claims:
- Immersing the gun in solvent or cleaning agents, or for a period longer than required for
the cleaning process as such
- Storing the gun inside the gun washing machine
- Cleaning the gun by means of ultrasound cleaning systems
- Cleaning of the display glass with pointed, sharp-edged or abrasive objects
- Exerting violent, inappropriate treatment
- Cleaning of display glass with pointed, sharp or rough objects (only SATA adam version)
III.7