TROUBLEShOOTING (continued)
LED PANEL
PROBLEM
CODE
LED Panel Code Flash & Alarm On (NOTE: Always turn off the power before cleaning and servicing).
• Transmission signal failure.
E81
• No water flow.
E90
• Dirt or scale on titanium plates.
• Low salt level / No salt.
E91
• Electrolytic cell cord is loose.
• Possible electrolytic cell failure.
• High salt level.
E92
• Water temperature too low.
E94
• Water temperature is
around 50°C (122°F).
E95
• System Error.
E96
E97
• Dry-fire Protection.
E99
• Water temperature sensor broken.
• After 72 hours of continuous
heating operation, the pump
END
will hibernate automatically.
The rapid heating function
is disabled.
• LED display is off
• Charging Failed
NO LED
• Control Panel failure.
DISPLAY
S AVE THESE INSTRUCTIONS
(344IO) SPA (JET + BUBBLE) ENGLISH 7.5" X 10.3" PANTONE 295U 08/09/2019
• Reset the RCD, restart all over again.
• Place the control panel within 5 m (16 ft) of the control base unit.
• Press and hold POWER button for 5 seconds to turn off and charge the
panel again.
• If problem persists, contact Intex Service Center.
• Turn off and unplug the control unit.
• Ensure the outlet cover grid is clean and free from obstructions.
• Clean or replace the cartridge, see Maintenance and Storage section.
• Ensure the in/outlet connections on the spa tub and filter pump are not blocked.
• Keep the spa water properly sanitized to ensure a clean and unclogged filter
cartridge.
• If problem persists, contact Intex Service Center.
• Remove the electrolytic cell for inspection. Clean it if necessary. See
"Maintenance".
• Add salt. See "Salt Level Information".
• Ensure that the cell cord is plugged firmly into the cell receptacle.
• Contact Intex Service Center. Replace the cell if needed.
• Partially drain the pool and refill it with fresh water. See "Salt Level Information".
• If problem persists, contact Intex Service Center.
• If the ambient temperature is below 4°C (39°F), we recommend not to use
the spa.
• Turn off and unplug the control unit, add some warm water to raise the
spa water temperature above 5°C (41°F), then press the
heat up the water to the desired temperature.
• If problem persists, contact Intex Service Center.
• Turn off and unplug the control unit. When the water has cooled down,
plug the RCD and restart all over again.
• Turn the heater off, then press the filter and jet buttons to lower the water
temperature.
• If problem persists, contact Intex Service Center.
• Turn off and unplug the control unit. Plug the RCD and restart all over again.
• If problem persists, contact Intex Service Center.
• Contact Intex Service Center.
• Contact Intex Service Center.
40
C
• Press the
button to re-active the filter pump.
• Press any button to reactivate the control panel.
• Reset the RCD, restart all over again and charge the control panel again.
• Make sure the surface between the back of the control panel and the
control base recessed channel is clean, dry and free of obstruction.
• If problem persists, contact Intex Service Center.
English
SOLuTION
40
C
Page 32
344
A
button to