GAS UTILISATION Alika 350160
This stove is intended for use with Primus gas Propane/Isobutane/
Butane in cartridges with designation 2202xx, 2206xx, 2207xx. (Red
Power Gas, green Summer Gas or brown Winter Gas). Alternatively,
an LPG cylinder that fits adapters attached to the stove (in certain
countries), or sold separately as an accessory.
Gas consumption is 3,0 + 3,9 kW 493 g/h for propane for model 35016x, 13300/11500 BTU/h.
The diameter of the bore in the nozzle of the stove's burner is 0.37/0.42 mm.
CHECKING THE STOVE.
is a leak on your appliance (smell of gas), take it outside immediately
into a well ventilated flame free location where the leak may be
detected and stopped. If you wish to check for leaks on your appliance,
do it outside. Do not try to detect leaks using a flame, use soapy water.
Contact Primus or your local dealership for replacement parts. You will
find contact information on the back page of this instruction booklet.
1.
Smell or listen for gas leaks from the gas cartridge.
putting some soapy water on the connection to the gas cartridge. If you see any bubbles, there is
a gas leak – DO NOT LIGHT the stove!
2.
The gas control
ing the gas cartridge.
knobs on the stove must be closed (turn clockwise to close) before connect-
Important: If there
If you are not certain, you can check by
EN