ASC5000 RPA
1. Undo the screws (D) on the control panel and lift it up.
2. Open the fastener for the flash memory card and pull out the
card (L).
3. Insert a new flash memory card and fasten it.
4. Lower the control panel and screw it down.
5. Close the control panel and reconnect power plug.
6. Switch on the unit and follow the instructions on the display.
I
NOTE
When you switch it on again, the values should be copied from the flash
memory card to the unit. To do this, switch to "Other selections" –
"Service" and enter the password "1518". Press ENTER to confirm the
following display messages.