3. Replace the drained oil receptacle (O) and the O-ring (P).
4. When replacing the cover (N), ensure that the lug (Q) is positioned
correctly.
5. Clip the drained oil receptacle into the snap lock.
9.12
Cleaning and maintenance
 Clean the exterior of the unit with a damp cloth as required. If neces-
sary, use a small amount of dishwashing detergent. Do not use sol-
vents or scouring agents.
 Check the service hoses (12) and (13) and the service couplings (14)
and (15) for damage regularly. Do not start up the
AirConServiceCenter if it is damaged.
EN
N
Service tasks
O
P
Q