Problem
Water is leaking
from the unit.
Cubes are partially
formed or are
white at the
bottom.
The ice cubes are
incomplete when
being dumped.
Noise during
operation
The ice maker
stops suddenly
while making ice.
The body of the
ice maker is
electrified.
Scale occurs
frequently inside
the machine.
Possible Cause
A few water drops fall to
the floor when you open the
door to take out ice from
ice storage bin.
Water supply connection
leaking.
Nut of water drain hole
leaking.
Drain hose connection
leaking.
Not enough water in the
water sump.
The sprinkler is blocked.
The feet are not leveled and
locked.
Certain sounds are normal. See "Normal Sounds".
The electricity is off.
The room temperature is
out of the stated range.
The ventilation louvers are
covered.
The grounding line isn' t in
the socket.
The hardness of the water is
too high.
Probable Correction
Normal condensation on the door or
some water together with ice. Take
care when you take out ice.
Tighten fitting. See "Connecting the
Water Line".
Tighten the nut.
Tighten fitting. See "Connecting the
Drain".
Check if the water supply pressure is
below 20 psig.
Check water supply; filter may be
restricted.
Check for a water leak at the water sump.
Check if water inlet valve is restricted.
Clean it; see "Interior Cleaning".
Level and lock the feet. See "Leveling
the Ice Maker".
Reconnect the power supply line.
Cut off the electricity; let the ice maker
stop working till the temperature
returns within the stated range.
Remove the obstruction.
Use a socket meeting the required
electrical standard.
Use a water-softening device installed
in front of the water inlet valve.
27