5. INSTALLATION.
Read and respect the Safety Information described in
•
Chapter of this document. Failure to obey some of the
instructions described in this manual can result in a serious or
very serious accident to persons in direct contact or in the
vicinity, as well as faults in the equipment and/or loads
connected to it.
During discharge, the equipment operates in IT (iso-
•
lated earth) neutral mode. This means that the neutral
is not directly connected to earth, providing an additional layer
of safety and stability in critical situations. To ensure optimal
and safe operation, follow the guidelines in the user manual
and contact your distributor if you have any questions.
5.1. RECEPTION OF THE DEVICE.
Pay attention to section 1.2.1. of the safety instructions -EK266
•
* 08- in all matters relating to the handling, movement and
location of the unit.
Use the most appropriate means to move the UPS.
•
Any handling of the device must be carried out in accordance
•
with the weights shown in the technical specifications
according to the model, indicated in chapter '9. Annexes'.
5.1.1. Reception, unpacking and contents.
Reception. Check that:
•
The data on the label affixed to the packaging correspond
to those specified in the order. Once the UPS is unpacked,
check the previous data with those of the equipment
nameplate.
If there are discrepancies, file the disagreement as soon
as possible, citing the equipment manufacture number and
the delivery note references.
There is no damage to the packaging that may have
occurred during transportation.
If there is damage, notify the carrier and indicate so on the
delivery note, and, as soon as possible, inform the supplier
/ distributor or, failing that, our firm.
Unpacking.
•
Remove the packaging to check the contents.
Complete the unpacking according to the procedure
in section 5.1.3.
Content.
•
Device:
1
46
2
3
5
7
9
Fig. 4. UPS packaging contents.
Item
Description
1
UPS
2
Quick guide
3
Warranty leaflet
4
USB communication cable
AC power cable - IEC 60309 13A (BS type only for UK 3
5
kVA versions)
AC power supply cable - IEC 10A, (Schuko type for
6
standard version and BS type for UK versions of 0.7
kVA, 1 kVA and 1.5 kVA)
7
Rack brackets and fixing screws
Mounting brackets for tower installation and fixing
8
screws
Kit of extendable rails for rack mounting and screws for
9
fastening
Tab. 2. List of contents UPS.
Optional battery module:
1
4
6
8
Quantity
1
1
1
1
2
1
2
2
1
2
SALICRU