Damage to property due to condensation build-up
Faulty storage can cause condensate to form in the device and impair the functionality of the device (e.g. storage out-
side the ambient conditions or temporary relocation from a cold to a hot environment).
Prior to installation, check the inner area for condensation and if necessary, allow it to dry sufficiently before in-
stallation
Storage in accordance with the technical data > Environmental data - see manual
ergy.com/de/downloads
2.6
Monitoring and protection functions
The following monitoring and protection functions are integrated in the device:
Overvoltage conductor/varistor to protect the power semiconductors from high-energy transients on the grid and
generator side
Device temperature monitoring system
EMC filters to protect the product from high-frequency grid interference
Grid-side grounded varistors to protect the product against burst and surge impulses
Islanding detection (anti-islanding) according to the current standards
IMI (Isolation Monitoring Interrupter) detection of a generator insulation fault.
NOTE
If the device is connected, the overvoltage conductors / varistors contained in the device have an impact on
the electrical system insulation resistance test as per HD 60364-6 / IEC 60364-6 Low-voltage installations-
Part 6: Verification.
IEC 60364-6 6.4.3.3 describes two options for this case. The first option is to disconnect devices with an
overvoltage conductor or, if this is not practicable, then the test voltage can be reduced to 250V.
3
Assembly and preparation
3.1
Selecting an installation location
DANGER
Risk of fatal injury due to fire or explosions
Fire caused by flammable or explosive materials in the vicinity of the device can lead to serious injuries.
›
Do not mount the device in an area at risk of explosion or in the vicinity of highly flammable materials.
CAUTION
Property damage due to gases that have an abrasive effect on surfaces when they come into contact with
ambient humidity caused by weather conditions!
The housing of the device may be seriously damaged by gases (ammonia, sulfur, etc.) if it comes into contact
with ambient humidity caused by weather conditions.
›
If the device is exposed to gases, it must be installed in a location that is visible.
›
Perform regular visual inspections.
›
Immediately remove any moisture from the housing.
›
Ensure that there is sufficient ventilation at the installation location.
›
Immediately remove dirt, especially on vents.
›
Failure to observe these instructions may result in damage to the device which is not covered by the
warranty.
NOTE
Access by maintenance personnel for service
Any additional costs arising from unfavorable structural or mounting conditions shall be billed to the cus-
tomer.
Installation space
As dry as possible, climate-controlled, the waste heat must be dissipated away from the device.
Unobstructed air circulation.
Close to the ground, accessible from the front and sides without requiring additional resources.
blueplanet gridsave 92.0 TL3-S blueplanet gridsave 110 TL3-S blueplanet gridsave 137 TL3-S
in the category "hybrid and battery inverter".
http://www.kaco-newen-
Side 135