E:0846 Range of the line pressure sensor was set below the pressure settings applied.
E:0856 Range of the internal pressure sensor was set below the pressure settings applied.
E:0866 Tension below the minimum level or incorrect DC polarity.
5.2 – CONTROLLED SHUTDOWN AND STOP ERRORS
None
5.3 - ALARMS
5.3.1 – Digital input alarms
A:2020 High oil filter differential pressure
5.3.2 – Analog input alarms
A:2118 High line pressure
A:2128 High outlet temperature
A:2138 High internal pressure
5.3.3 - Special function alarms
A:2808 High differential pressure
A:2816 Power loss occurred while compressor was in standby mode
5.4 - START-UP IMPEDIMENTS
None
5.5 - OPERATION IMPEDIMENTS
R:3123 Outlet temperature below the minimum operation temperature, the interface will allow that the motor starts when the temperature
is above the set value.
R:3137 Internal pressure PI above the impediment level set on the interface will pertmit that the motor starts when
the pressure drops below the set level.
5.6 - MAINTENANCE ALARMS
5.6.1 - Maintenance alarms
A:4804 Change oil filter
A:4814 Change air filter
A:4824 Change oil
A:4834 Check separating element
A:4844 Grease motor bearings
CONTROL II – LEDs INDICATION
The LED 1 is located on the electronic board between the connectors X07and X08 and can be seen from the back of the interface, without
removing the back protection cover. This LED supplies diagnostics information about different functions of Control II.
Production; internal testing