Safety Information
Air quality
• For optimum performance and maximum ma-
chine life we recommend the use of com-
pressed air with a maximum dew point of
+10°C. We also recommend the installation of
an Atlas Copco refrigeration-type air dryer.
• Use a separate air filter of type Atlas Copco
FIL. This filter removes solid particles larger
than 15 microns and also removes more than
90 % of liquid water. The filter must be in-
stalled as close as possible to the machine/
equipment and prior to any other air prepara-
tion unit such as REG or DIM (please see Air
Line Accessories in our main catalogue). Blow
out the hose before connecting.
Models which need air lubrication:
• The compressed air must contain a small quan-
tity of oil.
We strongly recommend that you install an At-
las Copco oil lubricator (DIM). This should be
set according to air consumption by the air line
tool according to the following formula:
L = Air consumption (litre/s)
D = Number of drops per min (1 drop = 15
3
mm
)
L* 0.2 = D
this applies to the use of long work cycle air
line tools. A single point lubricator type Atlas
Copco Dosol can also be used for tools with
short running cycles.
Information about Dosol settings may be found
under Air Line Accessories in our main cata-
logue.
Lubrication-free models:
• In the case of lubrication-free tools it is up to
the customer to decide on the peripheral equip-
ment to be used. However, it is no disadvan-
tage if the compressed air contains a small
quantity of oil e.g. supplied from a fog lubrica-
tor (DIM) or Dosol system.
• Note – This does not apply to turbine tools,
which should be kept oil free.
Compressed air connection
• The machine is designed for a working pres-
sure of 6–7 bar = 600–700 kPa = 87–102 psi.
• Blow out the hose before connecting.
6
© Atlas Copco Industrial Technique AB - 9836 099301 01
Installation proposal
Choosing the correct couplings, hose and clamps
can be a troublesome digging into details. To save
your time and to ensure correct capacity of the air-
line installation, from the tapping point to the tool,
we offer you an installation proposal.
For more information please read, Atlas Copco In-
dustrial Power Tools catalogue Ordering No. 9837
3000 01.
Handling
Operating instructions
See figure in Service instructions
Maintenance
Rust protection and internal cleaning
Water in the compressed air, dust and wear parti-
cles cause rust and sticking of vanes, valves etc.
This can be solved by flushing with oil (some
drops), running the machine for 5-10 seconds and
absorbing the oil in a cloth. Make it before longer
standstills.
Lubrication
The front motor ball bearing should be lubricated
with grease in conjuction with the regular overhaul
of the machine.
Use lubricants of good quality. The oils and
greases listed in the lubrication table are examples
of lubricants that can be recommended.
LSK 37