ZONE 1 HEATING PARAMETERS
P01
700
*Operating mode (0=Antifreeze, 1=Timed, 3=T.comfort)
P02
712
*Reduced ambient temperature
P03
720
*"Kt" curve slope
P04
721
*"Kt" curve drift
P05
726
*"Kt" curve adaptation
P06
741
Flow temperature setpoint (maximum value)
P07
742
*Enable modulating temperature if set = "---"
P08
750
*Ambient influence
P09
834
*Opening/Closing speed of mix valve
ZONE2 HEATING PARAMETERS
P10
1000
*Operating mode (0=Antifreeze, 1=Timed, 3=T.comfort)
P11
1010
*Comfort room temperature
P12
1012
*Reduced ambient temperature
P13
1020
*"Kt" curve slope
P14
1021
*"Kt" curve drift
P15
1026
*"Kt" curve adaptation
P16
1041
Flow temperature setpoint (maximum value)
P17
1042
*Enable modulating temperature if set = "---"
P18
1050
*Ambient influence
P19
1134
*Opening/Closing speed of mix valve
DHW PARAMETERS
Operating mode in DHW (with Remote Control)
P20
1620
0=always enabled, 1=according to hourly heating programme,
2= according to hourly DHW programme.
Anti-legionellosis function Disabled/Periodic (boiler with storage unit)
P21
1640
0=disabled, 1=periodic (depending on P22), 2=once a week
Periodic anti-legionellosis function enable (only if P21 =1)
P22
1641
1=daily, 2..6=intervals of 2..6 days, 7=once a week
P23
1663
Circulation temperature setpoint (additional DHW pump)
P24
5470
Preheating time for DHW circuit (1=10' -- 144=1440')
BOILER PARAMETERS
P25
2243
Minimum boiler off time
P26
2217
Anti-freeze setpoint
P27
2250
Pump post-circulation time
P28
2441
Max. fan speed (heating)
P29
2455
Minimum boiler off differential
SOLAR PLANT PARAMETERS (with accessory Expansion Unit)
P30
3810
Temperature - on differential
P31
3811
Temperature - off differential
P32
3850
Solar panel manifold overheating protection ("---" = disabled)
P33
5051
Maximum temperature of storage boiler
CONFIGURATION
P34
5700
Not used (Do NOT change this parameter)
P35
5710
Zone 1 heating circuit (1=enabled)
P36
5715
Zone 2 heating circuit (1=enabled)
P37
5890
Not used (Do NOT change this parameter)
P38
5931
*BX2 sensor input (first auxiliary sensor – section 11)
P39
5932
*BX3 sensor input (second auxiliary sensor – section 11)
P40
5977
*Input H5 (multifunction input – 18=Room thermostat)
P41
6020
*Configuration of accessory Expansion Unit
P42
6220
Software version
MAINTENANCE
P43
7045
Time after maintenance
P44
6704
View/Hide secondary fault internal code
BURNER CONTROL
P45
9512
Required ignition speed
P46
9524
Required minimum operating speed
P47
9529
Required maximum operating speed (high speed)
BOILER CONTROL PANEL PARAMETERS
P48
3
Unit of measurement (1=bar, °C – 2=PSI, °F)
P49
4
Control panel operation: (1=central, 0=local)
P50
5
Software version
* see "Accessories not included in supply"
xx: the value depends on the software version
(a): parameters read on the front boiler panel (fixed control panel)
(main zone)
(with accessory Expansion Unit)
(low speed)
xxx : the value depends on the type of boiler
(b): parameters read on the Remote Control
33
Factory
Minimum Maximum
setting
3
0
°C
16
4
1,5
0,1
-
0
- 4,5
-
1
0
°C
80
20
°C
80
20
50
%
1
s
180
30
°C
3
0
20
4
°C
16
4
-
1,5
0,1
-
0
- 4,5
-
1
0
°C
80
20
°C
80
20
%
50
1
s
180
30
-
0
0
-
0
0
-
7
1
°C
45
8
min
0
0
min
3
0
°C
5
-20
min
3
0
rpm
xxx
0
°C
10
0
°C
8
0
°C
4
0
°C
---
30
°C
90
8
-
---
-
1
0
0
-
0
-
33
0
0
-
0
-
0
0
18
-
0
-
0
0
---
-
0
xxx
0
1
0
rpm
xxx
0
rpm
xxx
0
rpm
xxx
0
-
1
1
-
1
0
xx
0
7104645.02 (1-01/12)
3
35
4
4,5
1
80
80
100
873
3
35
35
4
4,5
1
80
80
100
873
2
2
7
80
144
255
20
20
8000
20
40
40
350
90
1
1
43
19
19
32
7
99
240
1
8000
8000
8000
2
1
999