PP
Pressure range
03
3 bar
32
04
4 bar
33
05
5 bar
34
06
6 bar
35
07
7 bar
36
08
8 bar
37
09
9 bar
38
10
10 bar
39
11
11 bar
40
12
12 bar
41
13
13 bar
42
14
14 bar
43
15
15 bar
44
1)
16
16 bar
45
1)
17
17 bar
46
1)
18
18 bar
47
1)
19
19 bar
48
1)
20
20 bar
49
3)
21
21 bar
50
3)
22
22 bar
V1
3)
23
23 bar
V2
3)
24
24 bar
V3
25
25 bar
3)
P1
3)
26
26 bar
P2
3)
27
27 bar
P3
3)
28
28 bar
P4
3)
29
29 bar
P5
Notes
1)
Only for size: 0, 1, 2, 3, 5, 6, 7, D, E, F, G, J, K, L
2)
Only for size: 8, M
3)
Only for size: 7, 8, L, M
Other versions on request.
5.3 Product overview
5.3.1 Operating elements
6
5
3
4
1
Fig. 1: Operating elements overview
1 Pressure supply input connection
3 Exhaust
5 Proportional solenoid
7 Communication interface, sealing
cap with pressure compensation
membrane
9 2 buttons
AVENTICS™ Sentronic 625 | IM502079-014-R01 | English
2)
32 bar
M1
100 mbar
2)
33 bar
M2
200 mbar
2)
34 bar
M3
300 mbar
2)
35 bar
M4
400 mbar
2)
36 bar
M5
500 mbar
2)
37 bar
M6
600 mbar
2)
38 bar
M7
700 mbar
2)
39 bar
M8
800 mbar
2)
40 bar
M9
900 mbar
2)
41 bar
A1
0 ... 1 bar abs.
2)
42 bar
A2
0 ... 2 bar abs.
2)
43 bar
A3
0 ... 3 bar abs.
2)
44 bar
A4
0 ... 4 bar abs.
2)
45 bar
A5
0 ... 5 bar abs.
2)
46 bar
A6
0 ... 6 bar abs.
2)
47 bar
A7
0 ... 7 bar abs.
2)
48 bar
A8
0 ... 8 bar abs.
2)
49 bar
A9
0 ... 9 bar abs.
2)
50 bar
B1
0 ... 10 bar abs.
shutoff version
Vacuum
B2
0 ... 12 bar abs.
bypass version
Vacuum
B3
0 ... 16 bar abs.
shutoff version
Vacuum
B4
0 ... 20 bar abs.
0 ... 50 psi.
B5
0 ... 50 bar abs.
0 ... 100 psi.
B6
0 ... 100 bar abs.
0 ... 150 psi.
B7
0 ... 500 bar abs.
0 ... 200 psi.
XX
No internal sensor
1)
0 ... 250 psi.
VV
No internal sensor /
vacuum
10
9
2 Output connection
4 Through hole for mounting
6 Electrical supply
8 Connection for ground, M4
10 LC display
6 Assembly and installation
Before you start with the installation: Familiarize yourself with the basic specifica-
tions for assembly as early as possible in advance. See
g 6.3 Preparation.
6.1 Notes on safety
Danger of injury due to leaks
Leaks lead to uncontrolled escape of compressed air and can cause severe in-
juries.
Only use connection seals that are not made of teflon or hemp.
u
6.2 Planning
6.2.1 Installation conditions
General requirements
• Take the product into account when equalizing potentials in the system.
• Make sure that the product is installed in a manner that protects it from all
types of mechanical loads.
1)
Product-specific requirements
1)
• Mounting orientation. See
5)
• Compressed air specifications. See
• Recommendation: Use oil-free compressed air.
• When using oiled compressed air (not recommended):
– Maximum oil content. See
– Only use oils approved for AVENTICS products.
– Make sure that the oil content remains constant during the entire service
life of the product.
– Never change from oiled to oil-free compressed air.
• Only operate the product with a voltage source and control voltage suitable
for PELV. The voltage source must ensure secure electrical isolation of the op-
erating voltage from the mains in accordance with IEC / EN 60204-1 (accident
prevention).
• Never ground the 24 V side of the supply voltage.
• The product causes high-frequency interference. Take appropriate interfer-
ence suppression measures if there are any sensitive devices in the vicinity
and the product is used in environments in accordance with IEC 61000-2-4.
Ambient conditions
• Let the product acclimatize for a few hours before installation. Otherwise wa-
ter may condense in the housing.
• Keep the installation location free from vibration.
• Protect the product from direct sunlight and UV radiation.
7
• Make sure that there are no ferromagnetic sources near the product.
8
• Make sure that the exchange of ambient air is guaranteed to prevent the
product from overheating.
2
• Avoid increased output pressure tolerances: Make sure that high-frequency
radiation from interference-emitting devices is kept away from the product.
4
• If the product is installed near heat sources: Shield the product.
• Ensure that the shielding does not enclose the product.
6.2.2 Required accessories, materials and tools
Select material and tools that are suitable for your product configuration. De-
pending on the configuration, you will need further accessories.
Mounting material
Assembly requires the following material, which is not included in the scope of
delivery. Respect dimensions and tightening torques.
• 2x screws
• 2x seals
• 1x silencer
• 1x screw for ground
• 2x tooth lock washer for ground
g 6.2 Planning
WARNING
g 14. Technical
data.
g 14. Technical
data.
g 14. Technical
data.
and
18