Descargar Imprimir esta página

Pool Technologie DUO Instrucciones De Uso página 45

Gerador de cloro in-situ + controlador de ph

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 52
IMMEDIATE AUTOMATIC
MESSAGE
DISPLAYED/FAULT
DETECTED
Production
STOP
pH regulation
Yes
Yes
Yes
No
Yes
No
No
Yes
POSSIBLE CAUSE
VERIFICATIONS AND SOLUTIONS
Check that:
- the flow sensor is properly
connected to the electronics
unit.
- the flow sensor is activated
(see sensor settings).
Insufficient water
- the valves on the filtration
flow
circuit are open.
- the filter pump is working
properly.
- the filtration circuit is not
blocked.
- there is enough water in the
pool.
Loss of
communication
between the
control board and
Contact a professional.
the power board
of the electronics
unit
Add salt.
Automatic reactor
Change the pump if necessary.
filling failure.
Check that the water and salt
Lack of salt.
hoses are correctly primed.
Ensure the pH corrector
container is not empty.
Check the condition:
- filter with ballast.
- semi-rigid pipes.
- of the peristaltic pump.
- injection connector.
Perform a manual injection.
Series of 5
unsuccessful
Check that:
attempts to
- the peristaltic pump is
correct the pH
operating correctly.
- the pH corrector is correctly
injected.
Calibrate the pH probe.
OPTION TO
DEACTIVATE VIA
MENU
No
No
Yes
Yes
and
20

Publicidad

loading