Water hardness (°f)
Water hardness (mg/l)
Inversion frequency
(hours)
1) Press and hold down the bottom key, until the message In is displayed.
2) Press the bottom key: the current setting flashes.
3) Select an inversion frequency using the top key.
4) Confirm with the bottom key: the display freezes for a moment.
8.6. Setting the production setpoint
Possible settings: from 00 to 10, in increments of 1.
Default setting: 10.
Select a production setpoint using the top key (no confirmation required).
Important note: It is not possible to measure the level of free chlorine in your pool.
You will have to proceed empirically to adjust the setpoint.
Do not take into account the chlorine values given in the maintenance manual.
8.7. Boost mode (optional)
Boost mode sets the production value to its maximum for 24 hours but can be stopped at any point. This function
allows for meeting a need for chlorine.
I
Boost mode cannot substitute for a classic shock treatment in the event water is unsuitable for bathing.
Boost mode continues after powering off the electronic unit.
When the Boost mode terminates or stops, production continues according to the initial setpoint.
Switching on: Press the bottom button: the message bo appears.
Switching off: Press the top button.
8.8.
The socket marked
external control, or a cover position switch.
8.8.1. Pre-configuration
I
This configuration must be carried out.
1) Press and hold down the bottom key, until the message In is displayed.
2) Press on the top key x times until the message CG is displayed.
3) Press the bottom key (one of the following displays will flash).
4) Using the top key, move to position:
- CF, for connection to a flow sensor
- CE, for connection to an external control
- Co, for connection to a cover position switch
- oF to disable the
5) Press the bottom key to confirm: the display freezes for a moment.
0 to 2
2 to 5
0 to 20
20 to 50
16
14
(optional)
or
(depending on the electronic unit model) is used to connect a flow sensor, or an
socket (default setting).
5 to 8
8 to 12
12 to 20
50 to 80 80 to 120 120 to 200 200 to 400 400 to 600
12
10
20 to 40
40 to 60
8
6
4
> 60
> 600
2
13