2.9. Safety
2.9.1. Alarms
All alarms are activated by default.
Any alarm that is activated is immediately displayed on the screen.
To cancel an alarm: press the OK button.
As long as a detected fault remains, the corresponding alarm or warning is maintained, and the corresponding message
reappears a few moments after the acknowledgement.
MESSAGE
DISPLAYED/FAULT
DETECTED
Alarm
Empty pH container
Alarm
Flow
Alarme
Injection pH
Info
pH calibration
IMMEDIATE
AUTOMATIC
POSSIBLE CAUSE
STOP OF pH
CONTROL
pH corrector
Yes
container empty
Insufficient water
Yes
Flow sensor
problem
Series of 5
unsuccessful
Yes
attempts to
correct the pH
pH probe
incorrectly
calibrated
No
pH sensor
problem
CHECKS AND REMEDIES
Replace the pH corrector container.
Check that:
- the valves on the filtration circuit
are open.
- the
filter
flow
properly.
- the filtration circuit is not blocked.
- there is enough water in the pool.
Check:
- the connection of the sensor to the
electronics unit.
the condition of the sensor,
-
including the cable.
Ensure the pH corrector container
is not empty.
Check the condition:
- filter with ballast.
- semi-rigid pipes.
- of the peristaltic pump.
- injection connector.
Carry out a manual injection.
Check that:
- the peristaltic pump is working
properly.
- the pH corrector is correctly
injected.
Regulation
Regulation Corrector
- Volume
Calibrate the pH probe.
Calibrate the pH probe.
Check:
- the connection of the probe to the
electronics unit.
- the condition of the probe,
including the cable.
DISABLE VIA THE
pump
is working
pH
Setpoint
pH
Settings
OPTION TO
Settings - Alarms
MENU
Yes
No
Yes
Yes
11