Overload capability
• Voltage
• Current
Measuring Features
• Voltage range
• Current range (secondary winding)
• Frequency range
• Measured Quantities
Display features
• Phase sequence error indication
• Display type
• Active energy: 1 display, 9 digit - 2 tariffs
+ display import or export (arrow)
• Working tariff
• Display refresh period
Safety
• Protective class
• AC voltage test (EN 50470-3, 7.2)
• Degree of pollution
• Operational voltage
• Impulse voltage test
• Housing material flame resistance
• Safety-sealing between upper and lower housing part
Embedded communication Modbus
• Physical interface
• Internal termination resistor
• Baud rate
• Parity
• Stop Bit
• Address
• Isolation class
Optical metrological LED
• Front mounted red LED (meter constant)
IR Connectable Communication Modules
• For communication moduls connection (Modbus RTU / KNX)
Connection terminals
• Screwdriver for mains terminals
• Screwdriver for tariff and communication terminals slotted head
• Terminal capacity main current paths
• Terminal capacity for tariff and communication
Environmental conditions (storage)
• Temperature range
Environmental conditions (operating)
• Temperature range
• Mechanical environment
• Electromegnetic environment
• Installation
• Altitude (max.)
• Humidity
• IP rating
(*) The metering equipment must be installed inside a cabinet with IP rating IP51 or better.
MODBUS ADDRESS TABLE
LEGENDA
Register Access
R = the register is read only
W = the register is write only
Register
Register Tag
Address
4100
Firmware version
4101
Range overflow alarm (*)
Running tari
4102
(0 Tari 1 is currently in use
1 Tari 2 is currently in use)
4104
PID (Product Identification) bytes 1 and 2
4105
PID – bytes 3 and 4
4106
PID – bytes 5 and 6
4107
PID – bytes 7 and 8
PID – bytes 9 and 10
4108
4109
PID – bytes 11 and 12
4110
PID – bytes 13 and 14
Modbus Baud Rate (One of the following:
4112
1200, 2400, 4800, 9600, 19200, 38400)
Modbus Parity (0=None, 1=Even, 2=Odd)
4113
Modbus Stop Bits
4114
(1=One Stop Bit, 2=Two Stop Bits)
4115
Modbus Address (From 1 to 247)
continuous; phase/phase
1 second: phase/phase
continuous; phase/N
1 second: phase/N
continuous
Temporary (0,5 s)
phase/phase
phase/N
LCD backlightet
digit dimensions
min/max displayed energy
1-digit
indications
UL 94
RS485 - 3 Wire
adjustable
adjustable
adjustable
adjustable
proportional to active imp/exp Energy
head with Z +/-
solid wire min. (max)
stranded wire with sleeve min. (max)
solid wire min. (max)
stranded wire with sleeve min. (max)
Indoor
yearly average, not condensing
on 30 days per year (not condensing)
Type
N4 = numerical value (2 consecutive registers, 4 bytes)
N8 = numerical value (4 consecutive registers, 8 bytes)
ASCII = a pair of ASCII characters
Signed Unsigned
Register
Type
Access
Length (bytes)
R
R
R
R
ASCII
R
ASCII
R
ASCII
R
ASCII
R
ASCII
ASCII
R
R
ASCII
R/W
R/W
R/W
R/W
VAC
VAC
VAC
VAC
A
A
VAC
VAC
A
Hz
-
-
n° digits
mm x mm
kWh
-
s
class
kV
-
VAC
1,2/50 µs-kV
class
-
-
-
-
-
-
-
-
p/kWh
-
POZIDRIV
mm
mm
2
mm
2
mm
2
mm
2
°C
°C
-
-
-
meters
-
-
-
Register
&
Address
Float Integer format
(0 Numeric values are coded as floating point
4117
32 bit 1 Numeric values are coded as integers)
4119...4122
Active Energy (L1, T1, iported) [kWh]
4123...4126
Active Energy (L2, T1, imported) [kWh]
4127...4130
Active Energy (L3, T1, imported) [kWh]
4131...4134
Active Energy (Σ, T1, imported) [kWh]
4135...4138
Active Energy (L1, T2, imported) [kWh]
4139...4142
Active Energy (L2, T2, imported) [kWh]
4143...4146
Active Energy (L3, T2, imported) [kWh]
4147...4150
Active Energy (Σ, T2, imported) [kWh]
4151 & 4152
Active Power (L1) [kW]
4153 & 4154
Active Power (L2) [kW]
4155 & 4156
Active Power (L3) [kW]
4157...4160
Active Power (Σ) [kW]
4161...4164
Active Energy (L1, T1, exported) [kWh]
CT connected
built-in communication
Modbus
480
800
800
300
6
120
160 ... 480
92 ... 276
0.002 ... 6
45 ... 65
kWh
PHASE Err
3x4 digits-9 digits (Energy)
6 x 3
0,01 / 99999999.9
T1 or T2
1
II
4
2
300
6
V0
yes
D1, D0, Common (GND)
120 Ω
1200-2400-4800-9600
19200-38400
Odd, Even, None
1. 2
1-247
SELV circuit
10.000
yes
PZ1
0,8 x 3,5
0 (4)
0 (4)
0 (2,5)
0 (2,5)
-25 ... +70
-25 ... +55
M1
E2
yes
2000
75%
95%
IP51(*)/IP40
Signed Unsigned & Length (bytes)
U4 = 4 bytes, unsigned
U8 = 8 bytes, unsigned
S4 = 4 bytes, signed
S8 = 8 bytes, signed
Register
Register Tag
Access
R/W
R
R
R
R
R
R
R
R
R
R
R
R
R
Signed Unsigned
&
Type
Length (bytes)
N
8
U
8
N
8
U
8
N
8
U
8
N
8
U
8
N
8
U
8
N
8
U
8
N
8
U
8
N
8
U
8
N
4
4 S
N
4
4 S
N
4
4 S
N
4
8 S
N
8
U
8
7