2.2. Installation diagram
The pH corrector container must be kept 2 metres away from any electrical device or any other chemicals.
In order for acid fumes to be expelled outside the pool house, a venting system must be placed on the pH
possibly resulting in complete device failure. Personal protective equipment (glasses with side protection,
suitable glov
or the injection circuit
Never use hydrochloric acid, as this may lead to irreversible damage to the device and void the warranty.
Only use a sulphuric acid- or alkali-based pH corrector product recommended by your professional dealer.
Please note that use of a multi-acid pH corrector requires increased maintenance, and its use may also lead
to premature wear of the pH circuit and void the warranty. Refer to the pr
1: Temperature sensor
2: Reactor
3: Electronics unit
4: Ballast filter
5: Peristaltic pump
6: Pool Earth
7: Injection connector
8: pH probe
9: Ampero probe (specific installation manual)
10 &
11: Supports
12: Semi-rigid pipe
NON-CONTRACTUAL IMAGES
ELEMENTS NOT SUPPLIED:
13: Electricity supply
14: pH corrector container
15: Copper cable
16: Filter
17: Earthing rod
18: Heat pump
19: Filtration pump
20: Vent to outside
.