NATURAL GAS DANGERS AND WARNINGS
• Never store or use gasoline or other volatile substance in the vicinity of this fire table.
Natural Gas Connection
Connect a manual shut-off valve to gas supply line. Apply sealing compound or pipe thread tape of
the type resistant to the action of natural gas on all male pipe threads. Connect the end, with the
quick release connector, or the natural gas hose to manual shut-off valve at the gas supply.
!
WARNING
During any high pressure testing of the gas supply piping system at test pressures in excess of
½ psi (3.5 kPa), the appliance and its individual shut-off valve must be disconnected from the
gas supply piping system.
The outdoor fire table must be isolated from the gas supply piping system by closing the individual
manual shut-off valve during any pressure testing of the gas supply piping system at least equal to
or less than 1/2 psi (3.5 kPa).
!
WARNING
Burner valves are pre-tested at the factory to operate on natural gas. Do not attempt to convert
or change.