INSTALLATION
Connection of photocells
FCA2 COM FCC2
P1 P2 P3
P4 P5 P6
P15 P14 P16
ST1
FT1
ST2
FT2
FCA1
FCC1
46
Installation Manual
SCA
G4
G5
G6
G1
G2
G3
P7 P8
P11 P12
P22 P23
G7 G8
G9 G10
Courtesy
STOP
LOCK
24Vac
Lamp.
MOTOR2 (G2-G1-COM)
MOTOR1 (G2-G1-COM)
Light
We recommend installing interior and safety on
closings. If only one is installed, install the
exterior one. If a safety device is not installed,
make an electrical bridge in the corresponding
terminal of the control board.
Shown below is an example of the connections of a
KLPMUTO photocell as an exterior safety device.
1 Connect the NC contacts of the photocell (1) in the
corresponding terminal of the control board.
Correctly programme the microswitches DIP1 and
N
L
POWER
DIP2 (see the photocell instructions).
2 The 24Vac terminal can be used to feed the
photocell.
The bridge (2) is necessary if an interior photocell is
not installed.