14. OPERATION
Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clear the
air after you turn off the range.
After a power failure or during the range hood power up, a 5-second booting sequence is executed. Wait for the
control backlighting to turn off before use.
A. D
B
/C
L
ELAY
UTTON
ONTROL
i. When a blower speed is selected, press this button to activate the delay function. The delay button will light to its high intensity, then
to its mid intensity to indicate this function is activated; the selected blower speed button will alternate every 2 seconds between its
high intensity and its mid intensity. The blower will continue to operate for 5 minutes and will stop automatically. Selecting another
speed while the delay function is activated will not deactivate the function or reset the timer. To cancel the delay function, press the
delay button once again, or press the selected speed button which will also turn the blower off.
ii. When the blower is off, it is possible to lock the control interface in order to clean the glass panel.
To lock the control interface: Press and hold this button for 2 seconds. The button will light to its high intensity and flash three times,
it will then stay on its mid intensity to indicate that the control interface is locked.
To unlock the control interface: Press and hold this button for 2 seconds. The button will light to its high intensity and flash 3 times,
it will then fade out to its low intensity to indicate that the control interface is unlocked.
B. S
S
B
PEED
ELECTION
UTTONS
Press the button corresponding to the desired blower speed (from 1 for low speed to 4 for high speed). The chosen speed button will
light to its high intensity then fade to its mid intensity. To turn off the blower, press once more on the corresponding blower speed
button; the button light will fade to its low intensity.
NOTE: When blower is off, pressing on blower speed 1 button will cause the blower to start on second speed for a very short lapse of time,
and then resume to speed 1.
NOTE: To decrease the maximum airflow from 600 CFM to 300 CFM, follow the instructions of the 300 CFM CRT kit (included with the
unit, envelope no. 23894, or order SV23894 part).
H
S
™:
The hood is equipped with a HEAT SENTRY thermostat. If blower is ON at a lower speed setting and excessive heat is
EAT
ENTRY
detected above the cooking surface, it turns the blower up to third speed. When the temperature level drops to normal,
the blower will return to its original setting.
NOTE: When Heat Sentry is activated, the "DELAY OFF" function is inactivated.
The Heat Sentry can change the blower speed when excessive heat is detected above the cooking surface. If this
situation occurs and you must stop the blower, press on the third speed button or on the master ON/OFF button.
C. M
ON/OFF:
ASTER
When the blower and lights are off, press this button to turn the hood on to the last memorized speed level and light intensity. If
there are no memorized speed level and light intensity, speed will be set at level 1 and light intensity at 3. To turn off the blower
and the light simultaneously, press this button once.
A
HC0052
(D
F
B
OCK
OUBLE
UNCTION
UTTON
:
CAUTION
B
):
WARNING
!
13