The control unit is supplied by the manufacturer with
Automatic mode disabled. If you wish to enable the function,
proceed as follows: make sure that you have enabled
extended menu 1 (reported by alternately flashing T. MOT
PED Leds and T. PAUSA Led), by using the SEL key to
select the flashing CODE LED, and then press the SET key.
At this point the CODE LED lights up steady and
programming is finished.
Accordingly, using either the radio-control or the low voltage
push button panel to operate the gate, you will obtain the
following function: the first impulse controls opening until the
motor time expires, the second impulse controls gate closing.
If an impulse is sent before the motor time expires, the control
unit changes the direction of motion in the opening and
closing phases. Repeat the procedure if you wish to restore
the previous configuration.
B) PED. CODE ( Electronic Brake ) :
The control unit is supplied by the manufacturer with the
electronic brake function disabled. If you wish to enable the
function, proceed as follows: check that Extended Menu 1 is
enabled (T. MOT. PED and T. PAUSA LEDs start flashing
alternately), use the SEL button to move to the flashing PED
CODE LED then press the SET key: at that point the PED
CODE LED will light up steady and programming is complete.
Accordingly, the control unit slows down gate advancement
by inertia, when there is a stop or command to change the
direction of motion. Repeat the procedure if you wish to
restore the previous configuration.
C) INB. CMD. AP ( Anti-collision Function ) :
The control unit is supplied by the manufacturer with the Anti-
collision (pedestrian) Function disabled. If you wish to enable
the function, proceed as follows: check that Extended Menu 1
is enabled (T. MOT. PED and T. PAUSA Leds flash
simultaneously), use the SEL button to move to the flashing
INB. CMD. AP. LED and then press the SET button. At this
point the INB. CMD. AP. LED will light up steady and
programming is complete. The control unit will now operate in
Anti-Collision (pedestrian) mode.
If you wish to enable the Anti-Collision (pedestrian) function
for the closing phase only, repeat the operation described
above, pressing the SEL key twice (making the IN.CMD.AP.
LED flash quickly). Repeat the procedure if you wish to
restore the previous configuration.
D) LAMP/CORT. ( Deceleration ):
The control unit of the plant, the deceleration function and
obstacle detection during deceleration enabled. If, however,
you do not want to have any slowdown, you can exclude it: in
this way using automatic programming will no longer be
automatically activated during deceleration, or using the
Programming Times Motor, will no longer be given the
opportunity to plan the stages of slowing down. Once you
disable the slowdown phase will be necessary to repeat the
programming Automatic or manual Times Engine. If you want
to disable the slowdown proceed as follows: Make sure you
have enabled the Extended Menu 1 (indicated by the LEDs
flash alternately T.MOT.PED and Led T. PAUSE), use the
SEL button on the flashing of LED LAMP / CORT. and then
press the SET key: the LAMP / CORT. will shut down
permanently and programming is complete. If you want to re-
enable the deceleration phase, repeat the above operation,
by pressing the SEL button (getting the normal flashing LED
LAMP / CORT to enable the slow and obstacle detection
during the deceleration phase) when you press two times
(getting the fast blinking LED LAMP / CORT to enable the
slowdown without obstacle detection during the deceleration
phase).
E) PGM. AUT. ( Follow Me ) :
It is possible to set the "Follow Me" function on the control
unit: this function can only be programmed if a Pause Time
has already been programmed, and it is used to shorten the
Pause time to 5 sec after the photocell disengages, i.e. the
gate closes 5 seconds after the user has passed through. If
you wish to enable the function, proceed as follows: check
that Extended Menu 1 is enabled (T. MOT. PED and T.
PAUSA Leds flash simultaneously), use the SEL button to
move to the flashing PGM. AUT. LED and then press the
SET key: the PGM. AUT. LED
programming is complete. Repeat the procedure if you wish
to restore the previous configuration.
F) T. MOT. ( ENCODER ) :
The control unit supplied by the manufacturer can manage
Motors with a point Encoder; in the default configuration,
Encoder point control is disabled. If you wish to enable the
control, proceed as follows: check that Extended Menu 1 is
enabled (T. MOT. PED and T. PAUSA LEDs start flashing
alternately), use the SEL button to move to the flashing T.
MOT. LED then press the SET key: at that point the T. MOT
LED will light up steady and programming is complete.
Repeat the procedure if you wish to restore the previous
configuration.
EXTENDED MENU 2
The control unit is supplied by the manufacturer with the
possibility of directly selecting the main menu functions only.
If you wish to enable the functions described in Extended
Menu 2, proceed as follows: access Extended Menu 1 (as
described in the relative paragraph), then press and hold the
SET button down again for 5 seconds, after which amount of
time the T. MOT. PED and T. PAUSA LEDs will start flashing
simultaneously. The user then has 30 seconds to select the
functions for Extended Menu 2 using the SEL and SET
buttons. After another 30 seconds the control unit will go back
to the main menu.
----------------------
Led Reference Led Off Led On
A) CODE
remote PGM = OFF
B) PED. CODE
Photocell Test = OFF
C) IN.CMD.AP. Sens1 = rev. in CH
D) LAMP/CORT.Sens2 =stop AP/CH
E) PGM. AUT.
PUL=PUL – BL=BL
F) T.MOT.
PUL=PUL – BL=BL
G) T. MOT. PED.
H) T. PAUSA
A) CODE ( Remote radio-control programming ) :
The control unit allows the transmission code to be
programmed, without using the SEL button directly on the
control unit, but remotely.
The Radio-control can be remotely programmed as follows:
continuously sending a previously-memorised radio-control
code for more than 10 seconds. At this point the control unit
switches to programming mode, as described above for the
CODE LED in the main menu.
The control unit is factory supplied with the remote
transmission code programming function disabled. If you wish
to enable the function, proceed as follows: check that
Extended Menu 2 is enabled (T. MOT. PED and T. PAUSA
LEDs flash simultaneously), use the SEL button to move to
the flashing CODE LED, then press the SET key: at this point
the CODE LED will light up steady and programming is
complete. Repeat the procedure if you wish to restore the
previous configuration.
B) CODE PED. (Photocell Test) :
The control unit is factory supplied with Photocell Test
programming disabled. If you wish to enable the function (in
accordance with Standard EN 12453), proceed as follows:
check that Extended Menu 2 is enabled (T. MOT. PED and T.
PAUSA Leds flash simultaneously), use the SEL button to
move to the flashing CODE PED. LED then press the SET
key: at this point the CODE PED. LED will light up steady and
14
will light up steady and
EXTENDED MENU 2
-----------------
remote PGM = ON
Photocell Test= ON
Sens1 = brief rev. AP/CH
Sens2 = brief rev. AP/CH
PUL=AP - BL=PED
PUL=AP - BL=CH
Simultaneous ON/OFF flashing
Simultaneous ON/OFF flashing