Technical data
Electrical data in-
Mains voltage
put 230 V
Mains frequency
Mains current
Mains fuse
Efficiency
Effective power
No-load power consumption
Protection class (with ground conductor)
Maximum permitted mains impedance at the interface
(PCC) to the public grid
Mark of conformity
EMC device class
Standards 230V
IEC 60068-2-6
IEC 60068-2-29
EN 60335-1
EN 61000-3-2
EN 61000-6-2
EN 61000-6-4
Electrical data in-
Mains voltage
put 120 V
Mains frequency
Mains current
Mains fuse
Efficiency
Effective power
No-load power consumption
Protection class (with ground conductor)
Maximum permitted mains impedance at the interface
(PCC) to the public grid
Mark of conformity
EMC device class
Sinusoidal vibration (sine 10-55 Hz; 20 cycles / axis; acceleration 5 g)
Repetitive shock (25 g / 6 ms / 1000 shocks)
EN 60335-2-29
(EN 61000-4-2, EN 61000-4-3, EN 61000-4-4)
(EN 61000-4-5, EN 61000-4-6, EN 61000-4-11)
(Class A)
~ 230 V AC ±15%
50/60 Hz
max. 2.9 A eff.
max. 16 A
max. 95%
max. 420 W
max. 1.7 W
I
none
CE
A
~ 120 V AC ±15%
50/60 Hz
max. 7.3 A eff.
max. 20 A
max. 93%
max. 420 W
max. 6.9 W
I
none
cTÜVus
A
57