9.6 Cautions
1. The induction hotplate must be installed by qualified personnel or
technicians. We have professionals at your service. Please never
conduct the operation by yourself.
2. The hob will not be installed directly above a dishwasher, fridge,
freezer, washing machine or clothes dryer, as the humidity may
damage the hob electronics
3. The induction hotplate shall be installed such that better heat
radiation can be ensured to enhance its reliability.
4. The wall and induced heating zone above the table surface shall
withstand heat.
5. To avoid any damage, the sandwich layer and adhesive must be
resistant to heat.
6. A steam cleaner is not to be used.
9.7 Connecting the hob to the mains
power supply
This hob must be connected to the mains power supply only by a
suitably qualified person.
Before connecting the hob to the mains power supply, check that:
1. the domestic wiring system is suitable for the power drawn by the hob.
2. the voltage corresponds to the value given in the rating plate
3. the power supply cable sections can withstand the load specified on the
rating plate. To connect the hob to the mains power supply, do not use
adapters, reducers, or branching
devices, as they can cause overheating and fire.
The power supply cable must not touch any hot parts and must be positioned
so that its temperature will not exceed 75˚C at any point.
Check with an electrician whether the domestic wiring system is
suitable without alterations. Any alterations must only be made by a
qualified electrician.
The power supply should be connected in compliance with the relevant
standard, or a single-pole circuit breaker. The method of connection is
shown below.
35
V.2

Publicidad

loading

Este manual también es adecuado para:

Emih900-fx