Descargar Imprimir esta página

Polar UA037 Manual De Instrucciones página 9

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 47
Fault
UV indicator light is off
after the UV button is
pressed
UV indicator light flashes
once every second
UV indicator light flashes
once every 3 seconds
UV indicator light flashes
twice every 3 seconds
UV indicator light keeps
illuminating for 2 seconds
then going out for 1
second
Technical Specifications
Note: Due to our continuing program of research and development, the specifications herein may be
subject to change without notice.
Model
Voltage
UA037
220-240V~
50Hz
Dimensions
H x W x D mm
590 x 380 x 477
UA037_ML_A5_V1_20240118.indb 9
UA037_ML_A5_V1_20240118.indb 9
Probable Cause
Door is open
Water Sterilization failure + Box
Sterilization failure
Water Sterilization failure
Box Sterilization failure
When the UV lamp has been
working up to 10,000 hours, the
UV lamp needs to be replaced
Power
Current
Bin storage
185W
1.3A
Net Weight
25.4kg
Solution
Close the door and power off for
5 minutes, then restart the unit. If
problem still persists, call POLAR agent
or a qualified technician
Call POLAR agent or qualified technician
Max Ice Making
Capacity
3.5kg
20kg/24 hours
EN
Refrigerant
R600a 38g
9
2024/1/18 14:38
2024/1/18 14:38

Publicidad

loading