Fill the enclosed filter balls into the tank. Insert the base of the tank into the recess in the pump plate. Make sure
that the drain plug is pointing outwards.
Clean the edge of the tank opening thoroughly.
Then place the O-ring on the opening and attach the cover to the tank using the clamp (the direction of the water
inlet on the valve should be opposite the water outlet of the pump).
Connect the tank to the pump using the hose, hose clamps and hose adapters.
Please carefully note for the installation
1. Make sure the filter is working under pressure and using a pressure control valve when the systems using a
booster pump.
2. If the pump position is lower than the water level as recommended, it requires installing an isolation valve. It
could stop the water return back for general care and maintenance.
3. Reducing the connect adaptors and hose connecting bending as less as possible. Decreasing the water flow
scrub, it could reach the maximum effective.
4. Ensure solvents are not excessively applied to fittings as this could run into o-ring and cause damage of the
sealing's.
5. Do not over tighten fittings or adapters.
6.3.
Installation of pump inlet and outlet hose
The pump is developed according to the latest technology. These preventive actions during installation will ensure
a trouble-free operation for many years. Use a inlet pipe with the same diameter as the suction port of the pump.
The weight of the plumbing's and fittings is to be independently supported and not carried by the pump.
The pump inlet must be installed under the water level of the pool, because the pump works with an in-
take water supply.
For easier maintenance and care, we recommend the installation of an isolation valve. The advantage is, that by
closing the isolation valve no water runs out of the pool
,
that there is always a sufficient quantity of water in the filter tank before starting.
Make sure
If the pump does not run, observe the notices in the troubleshooting/tips section.
Make sure, all inlet and outlet valves are open, before priming the pump. Otherwise this could cause severe
damage of the pump.
6.4.
Fixed installation
For fixed installation of the electrical connection, make sure the plug can be easily reached and
is visible. For fixed installation the pump should be placed on a solid, horizontal surface.
.