DISPOSING OF THE UNIT

To dispose of the equipment at the end of its life,
contact the reseller for a quote or for the regulations on
disposal which apply to the unit.
This symbol indicates that separate collection of waste
electrical and electronic equipment is mandatory for
scrapping.
7.1

Instructions for disposal

For electrical and electronic equipment European
directive 2002/95/EC, 2002/96/CE and 2003/108/EC
(RAEE)
At the time of disposal, at the end of the lifetime of this
equipment, you must:
1. Render the machine inoperative, remove the plug
and cut off the power supply cable close to where it
comes out of the machine.
2. DO NOT dispose of the equipment as urban waste
and recycle it, by taking the materials to suitable
recycling centres.
3. Contact the reseller for the closest authorised
recycling centres for the disposal or for the collection
of old equipment when purchasing new equipment.
4. Stick to the standards for correct waste
management, to prevent potential effects on the
environment and human health. Unauthorised
disposal will result in administrative sanctions for the
offenders.
24
- EN
i

Installation requirements

THE INSTALLATION SHALL BE CARRIED OUT ONLY
BY QUALIFIED PERSONNEL AND WITHIN THE
SCOPE OF THE INSTRUCTIONS PROVIDED IN
THIS MANUAL.
Install the machine in a covered and dry area.
The installation of the machine requires a free space of
at least 270x270cm (106"x106") (Fig.i-1).
Make sure that from the operating position the user can
see all of the machine and the surrounding area.
The operator shall forbid, in such an area, the presence
of non authorized persons and of objects which may
create possible hazards.
The machine shall be installed on a horizontal floor
preferably even. Do not install the machine on a sinking
or irregular floor.
If the machine is installed on a raised floor, the floor
must have a capacity of at least 5000 N/m² (500kg/m²
or 110lbs
sqft). The machine must be secured to the
x
floor through the holes provided in the cabinet.
Expansion screws 12x120mm shall be used.
Drill 12mm holes in the floor flush with the holes
provided in the cabinet.
Place the nogs into the holes drilled in the floor and
move the machine so that the holes of the cabinet are
flush with the holes in the floor. Tighten the screws at 70
Nm (51 ft
lb).