ERROR CODES, CAUSES AND SOLUTIONS :
Code
Defects
Protection
against
high or low
TP
temperatures
The motor wheel
or motor does
not turn
BP
Voltage overload
OL
Phase loss
LP
View
Possible causes
Temperature above
90°C or below -5°C.
The pump has
sucked in dirt and the
impeller is blocked.
The damage bearing
has frozen the motor
shaft.
The output amperage
is too high.
The connection of
a phase wire to the
input is missing.
Solution
Wait until the temperature
returns to normal (5°C to
60°C).
The pump will attempt to
restart automatically in 6
seconds. If restart fails, the
user must check the wheel
and motor when the power
is off.
Send it to a professional
repair center.
The pump will try to restart
automatically within 6
seconds if it is not damaged.
Send it to a professionnal
repair center.
The pump will try to restart
automatically in 6 seconds
after the phase wire is
properly connected.