Hydraulic connection
The hydraulic connections must be made in a rational way using the connections on the insert template. To ease connection of the pipes, we have prepared
all hydraulic connections on the rear, leaving space to make the connections easily.
The insert can be coupled to any other boiler already installed in the system; naturally it is indispensable to insert the due safety devices and shut-offs
according to the system used.
N.B.: The insert can be installed with closed expansion vessel as long as it is equipped with fuel loading stop device, safety manual rearm
thermostat and acoustic alarm, which intervene if the temperatures are too high.
The insert can be installed in the same room as another boiler only if this is the sealed chamber type.
THE INSERT MUST BE INSTALLED EXCLUSIVELY BY QUALIFIED STAFF. SCRUPULOUSLY COMPLY WITH THAT STATED IN THIS GUIDE.
ALL LIABILITY IS DECLINED FOR DAMAGE CAUSED BY INCORRECT MOUNTING.
THE NETWORK WATER INLET PRESSURE MUST NEVER EXCEED 2.5 BAR; RECOMMENDED WORK PRESSURE: 1.2 BAR.
DO NOT PASS ELECTRIC CABLES IN THE IMMEDIATE VICINITY OF THE FLUE GAS PIPE, UNLESS THEY ARE INSULATED WITH SUITABLE
MATERIALS.
IF THE WATER HAS HARDNESS THAT EXCEED 28 °f AN ANTI-LIME SCALE DEVICE MUST BE INSTALLED. THIS MUST BE CHOSEN ON THE
BASIS OF THE FEATURES OF THE WATER.
COMMISSIONING
Filling the system for the first time
After having connected the insert, fill the system as follows:
Check pipe sealing, of the expansion vessel and the circulation pump;
Open the insert air vent valve (jolly);
Open the ball valve in order to fill the system. Act very slowly to allow the air to escape from the insert through the air vent valve; the best work
pressure is 1.2 bar;
If necessary, very slowly loosen the pump bleeding plug, making the fluid flow for a few seconds;
Bleed all radiators and any other deaeration systems present in the system in order to ensure that there are no air bubbles.
When installation has been completed, for the first days of functioning it is recommended to check the tightness of all hydraulic joints.
The insert system can be emptied from the cock positioned near to the hydraulic connections behind the appliance (see "SYSTEM DRAIN COCK).
In intensely cold periods it is good practice that the heating system remains running. In the case of prolonged absence, anti-freeze must be added
to the heating water or the system must be completely emptied.
In a system subject to being emptied frequently it is indispensable that filling is performed with water that has been appropriately treated to eliminate
hardness that can lead to lime scale deposits.
Pellet loading and connection to the electric network
Perform the following operations:
Fill the pellet tank from the relative front drawer paying attention not to exceed the tank load limit; for commissioning it is recommended to pour a handful
of pellets into the brazier in order to prevent the time necessary for filling the entire screw feed channel (this operation must be performed every time the
insert remains without pellets);
Connect the insert to the electric plant using the cable supplied;
Place the switch positioned on the rear of the insert at "( "׀on);
Switch the insert on using the relevant ignition key on the control panel. See the instructions below.
It is recommended to use top quality pellets so as not to compromise the functionality of the insert itself. Damaged caused by out-of-date pellets
are not covered by the warranty.
Insert control panel
The insert control panel manages all of the circuit board functions, which make the insert operate.
It is therefore possible to:
Switch the insert on and off;
Select the insert power level (from 1 to 5);
Program the weekly chrono-thermostat;
Check the temperature in the boiler, the flue gas temperature and all LEDs of the various functioning devices (water pump, flue gas intake device,
ignition resistance, pellet load screw feed,...);
Display the alarms produced (see "Alarms" section).
The insert is supplied with the remote control, as per standard, that can perform the following operations:
SWITCH ON/OFF;
INCREASE/DECREASE POWER;
INCREASE/DECREASE TEMPERATURE.
The insert must only be used after this user guide has been read completely.
11