Hydraulic connection
The hydraulic connections must be made in a rational way using the connections on the thermo stove template. To ease connection of the pipes, we have
prepared all hydraulic connections on the rear, leaving space to make the connections easily.
The thermo stove can be coupled to any other boiler already installed in the system; naturally it is indispensable to insert the due safety devices and shut-offs
according to the system used.
N.B.: The thermo stove can be installed with closed expansion vessel as long as it is equipped with fuel loading stop device, safety manual rearm
thermostat and acoustic alarm and SICURO top system, which intervene if the temperatures are too high.
The thermo stove can be installed in the same room as another boiler as long has this has a sealed chamber.
THE THERMO STOVE MUST BE INSTALLED EXCLUSIVELY BY QUALIFIED STAFF.
ALL LIABILITY IS DECLINED FOR DAMAGE CAUSED BY INCORRECT MOUNTING.
THE NETWORK WATER INLET PRESSURE MUST NEVER EXCEED 3 BAR; RECOMMENDED WORK PRESSURE: 1.2 BAR.
DO NOT PASS ELECTRIC CABLES IN THE IMMEDIATE VICINITY OF THE FLUE GAS PIPE, UNLESS THEY ARE INSULATED WITH SUITABLE
MATERIALS.
IF THE WATER HAS HARDNESS THAT EXCEED 28 °f AN ANTI-LIME SCALE DEVICE MUST BE INSTALLED. THIS MUST BE CHOSEN ON THE
BASIS OF THE FEATURES OF THE WATER.
COMMISSIONING
Filling the system for the first time
After having connected the thermo stove, fill the system as follows:
Check pipe sealing, of the expansion vessel and the circulation pump;
Open the ball valve in order to fill the system. Act very slowly to allow the air to escape from the thermo stove through the air vent valve; the best work
pressure is 1.2 bar;
If necessary, very slowly loosen the pump bleeding plug, making the fluid flow for a few seconds;
Bleed all radiators and any other deaeration systems present in the system in order to ensure that there are no air bubbles;
Regulate the float dipstick in a way that the exchangers are completely inside the thermo stove water.
After having filled the system and the boiler body, it is recommended to close or regulate the ball valve in a way that the inlet pressure at the float is not
particularly high (LESS THAN 1 BAR).
When installation has been completed, for the first days of functioning it is recommended to check the tightness of all hydraulic joints.
In intensely cold periods it is good practice that the heating system remains running. In the case of prolonged absence, anti-freeze must be added
to the heating water and that inside the boiler body.
In a system subject to being emptied frequently it is indispensable that filling is performed with water that has been appropriately treated to eliminate
hardness that can lead to lime scale deposits.
NEVER RUN THE THERMO STOVE WITHOUT WATER IN THE BOILER BODY BECAUSE, AS WELL AS NOT HEATING, FUNCTIONING AND
DURATION OF THE SAME COULD BE COMPROMISED.
DO NOT USE DISTILLED WATER.
NEVER EMPTY THE WATER INSIDE THE THERMO STOVE SO AS NOT TO COMPROMISE THE DURATION OF THE SAME.
Pellet loading and connection to the electric network
Perform the following operations:
Fill the pellet tank; for commissioning it is recommended to pour a handful of pellets into the brazier in order to prevent the time necessary for filling the
entire screw feed channel (this operation must be performed every time the thermo stove remains without pellets);
Connect the thermo stove to the electric plant using the cable supplied;
Place the switch positioned on the rear of the thermo stove at "( "׀on);
Switch the thermo stove on using the relevant ignition key on the control panel. See the instructions below.
It is recommended to use top quality pellets so as not to compromise the functionality of the thermo stove itself. Damaged caused by out-of-date
pellets are not covered by the warranty.
Thermo stove control panel
The thermo stove control panel manages all of the circuit board functions, which make the thermo stove operate.
It is therefore possible to:
Switch the thermo stove on and off;
Select the power level of the thermo stove;
Program the weekly chrono-thermostat;
Check the temperature in the boiler, the flue gas temperature and all LEDs of the various functioning devices (water pump, flue gas intake device,
ignition resistance, pellet load screw feed,...);
Display the alarms produced.
The thermo stove is supplied with the remote control, as per standard, that can perform the following operations:
SWITCH ON/OFF;
INCREASE/DECREASE POWER;
INCREASE/DECREASE TEMPERATURE.
The thermo stove must only be used after this user guide has been read completely.