Options and Accessories.
The Notecart Unifit comes prepared for a variety of options and accessories which to improve the
use and functionalities of the cart. None of these are supplied with the cart, and must be
purchased as extras besides from your local reseller. If any questions, kindly refer to your local
reseller, or contact Leba innovation directly at our contact info below.
Timer unit
The timer unit is used for controlling charging schedules for the Notecart Unifit. This has a 7-day
rotating schedule with up to 18 different settings.
The timer unit is installed in the back of the Notecart Unifit in the middle between the top power
supply cable tray and nr. 2
Installing the Timer:
Remove the Cable from the Main power supply
unit connecting the internal sockets "C" and "D"
under tech diagram explanation. Replace this
cable with the timer's cables, so that the timer
now controls the power directed to the 4 x C13
outlets powering the power panels. Read user
instructions for the timer which is included in
the Timer unit purchase for setup of the unit.
Thermostat heat controller
The Thermostat heat controller is a unit with adjustable temperature activation for the Ventilation
fan already build into the Notecart unifit. This is popular when the Notecart is placed in Classrooms
or at locations where noise is a nuisance to take into consideration. The Thermostat can be
adjusted to activate between 10° to 45°, whereas it will start up the ventilation fan in the Notecart
Unifit.
Installing the Thermostat:
The Thermostat is placed in the top of the Notecart
Unfit in the back. 4 rails on the stiffening bar where
you slide the Thermostat into place, and lock it with
the snap rivet included. Replace the cable C14 in the
Main power supply unit which gives power to the
Ventilation fan, and insert the C14 cable from the
Thermostat instead. Then take the outlet cable from
the Thermostat C13 and connect it together with the
Ventilation fan C14 cable. The Ventilation fan is now
controlled by the thermostat.