Remote Control - Kieboom Laser KL850 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 31
Care of Your Electronic Laser Detector
This instrument is gasket sealed for water and dust protection. Use a soft, dry cloth to remove any
dirt or moisture from the instrument before storage. Do not use benzene, paint thinner, or other
solvents to clean the instrument. Remove batteries before long-term storage of the instrument.
Specifications
D D e e s s c c r r i i p p t t i i o o n n
Dimensions:
Weight:
Range:
Beam Detection
Sensitivity:
(sensitivity based on standard conditions with most lasers; may vary slightly due to
make,manufacturer, beam size, or working conditions)
Readout:
Power:
Warranty:

REMOTE CONTROL

RC700 Remote Control Operation (Fig. 23) - For models KL850V, and
only
This section covers the use of the remote control (Cat. #57-RC700). The remote controls all the
functions except power, ADS, and calibration features, with a range of up to 100 feet (30m).
Requires 2 'AA' Alkaline batteries.
NOTE: When using the remote in Line Position Mode, the LEFT and RIGHT buttons can be used to
position the reference line regardless of the instrument being in Rotation, Spot, or Sweep Mode.
(1) Variable Rotation – places instrument in Rotation Mode and adjusts to preset rotational speeds.
(2) Left Arrow and (3) Right Arrow– Line positioning in laydown position and Grade Adjustment
X-Axis – Only in manual mode.
(4) Up Arrow and (5) Down Arrow- Grade Adjustment Y-Axis- Only in manual mode / When in
laydown position, grade adjustment of the leveling axis (Only in Manual Mode).
(6) CCW and (7) CW – positions the laser in Spot and Sweep modes.
(8) Scan/Sweep Mode – places instrument in Scan/Sweep Mode and adjusts to preset angles.
(9) Manual – Places the instrument in manual grade if ADS is not selected. In laydown position,
allows manual adjustment of the laser.
(10) Sleep – places the instrument into a "Sleep" mode by shutting down all functions except front
panel LEDs. Pressing any other remote button will put the instrument back into its last mode of
operation. The instrument will shut off after 2 hours if no other remote button is pressed.
L L S S 4 4 4 4 0 0
6.6" h x 3" w x 1" d (169mm x 76mm x 25mm)
10 oz. (275g)
Up to 1000' (305m)
Fine +/- 0,75 mm
Medium +/- 1,5 mm
Coarse,+/- 3 mm
LCD, front and rear windows
Two AA batteries; provides 3 months of typical usage
1 year (For warranty conditions see "Warranty")
KL850 • KL850V • KL850GR • 29

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Kl850vKl850gr

Tabla de contenido