ENGLISH
"Holiday" Function
Special mode of operation: manually enabled and useful if the user leaves the room for a longer period of time.
Operation includes:
- fixed "30% less than the Minimum " speed (no other speeds, no OFF equipment);
- environment sensors not enabled (remote inputs not actived);
- bypass always closed.
When the mode is active, the message "Holiday" appears on the display: see "Home Page" in the "Operation
with remote control display" section.
NOTE: Activating the Mode "Holiday" will be deactivate other product functionings/selections.
To re-activate other product functionings/selections, need to deactivate the Mode "Holiday" before.
For more details on how to activate / deactivate the function, see "Activating / deactivating Holiday" in the
"Operation with remote control
display".
"By-Pass MAN" Function
Special mode of operation: manually enabled and useful if you want to force air replacement without heat
recovery.
The operating principle is the same as: "By-Pass" function.
NOTE: If manually enabled, the "By-Pass MAN" function will remain active for 12 h. After this period, the "By-
Pass MAN" function will come back to: Not enabled.
NOTE: (In case of "By-Pass MAN" Enabled) However you can manually deactivate the function, setting "NO"
on "By-Pass MAN Menu". After Deactivating, the operating principle will be come back the same of "By-Pass"
function.
NOTE: In case of "No-Frost" function active, you can not manually activate the "By-Pass MAN" function.
When the function is active, the message "By-Pass" flashing appears on the display: see "Home Page" in the
"Operation" and use ". For details on how to activate/deactivate the function, see "Activating/deactivating By-
Pass MAN" in the "Operation with remote control display" section.
"Quiet" Function
This is a particular operating mode: if the user needs to temporarily disable the appliance from running at Vmax
(for example to exceed the RH relative humidity threshold set in the dedicated menu), this function is available
which can be programmed by the user. In the dedicated menu, you will have to set the daily time slot in which
the equipment will be inhibited from switching to Vmax mode in order to limit the noise within the pre-
established time slot.
This function is very useful during the night time slot