Location Requirements
Select a location that provides minimum exposure to wind and
traffic paths. The location should be away from strong draft
areas.
Do not obstruct flow of combustion and ventilation air.
Clearance to combustible construction for burner:
A minimum of 36" (92 cm) must be maintained between
the front, sides and back of the burner and any
combustible construction.
A 36" (92 cm) minimum clearance must also be maintained
below the cooking surface, and the burner shall not be
used under overhead combustible construction.
Product Dimensions
Built-In Outdoor
Side Searing Burner Enclosure
The enclosure opening for the built-in outdoor side searing
burner is to be a minimum of 11.5" (29.2 cm) wide x 20.75"
(52.7 cm) long x 7.3" (18.4 cm) deep.
This built-in outdoor side searing burner is only for installation in
a built-in enclosure constructed only of non-combustible
materials. Non-combustible materials could be brick, firewall or
steel. Do not use wood or other combustible materials for built-
in enclosure.