Burner Requirements for High Altitude
Input ratings shown on the model/serial rating plate are for
elevations up to 2,000 ft. (609.6 m).
For elevations above 2,000 ft. (609.6 m), ratings are reduced at
a rate of 4% for each 1,000 ft. (304.8 m) above sea level.
Orifice conversion is required. See "Assistance" section to
order.
Gas Supply Line Pressure Testing
Testing above 1/2 psi (3.5 kPa) or 14" (35.5 cm) WCP
(gauge):
The side searing burner and its individual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures greater than
1/2 psi (3.5 kPa).
Testing below 1/2 psi (3.5 kPa) or 14" (35.5 cm) WCP
(gauge) or lower:
The side searing burner must be isolated from the gas supply
piping system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping system at
test pressures equal to or less than 1/2 psi (3.5 kPa).
Gas Connection Requirements
This side searing burner is equipped for use with a 20 lb LP gas
fuel tank (fuel tank not supplied). A gas pressure regulator/hose
assembly is supplied.
A
A.
Gas pressure regulator/hose assembly
It is also design-certified by CSA International for local LP gas
supply or for Natural gas with appropriate conversion.
20 lb LP Gas Fuel Tank
The 20 lb LP gas fuel tank must be mounted and secured.
1.
Open cabinet doors (if applicable).
2.
Loosen the tank tray locking screw.
3.
Place the 20 lb LP gas fuel tank bottom collar into the
mounting hole in the tank tray.
4.
Tighten the locking screw against the bottom collar of the
20 lb LP gas fuel tank to secure.
5.
Close cabinet doors (if applicable).
A
A.
Locking screw
B.
Tank tray
C.
20 lb LP gas fuel tank tray
Make sure the tank is firmly secured in an upright position.
LP Gas Conversion Using a Local LP Gas Supply
If you want to convert to local LP gas supply, contact your local
gas company for specific instructions.
Natural Gas Conversion
Conversion must be made by a qualified gas technician. The
qualified Natural gas technician shall provide the Natural gas
supply to the selected side searing burner location in
accordance with the National Fuel Gas Code ANSI
Z223.1/NFPA 54 - latest edition, and local codes. For
conversion to Natural gas, the Natural Gas Conversion Kit
supplied with the side searing burner must be used. See the
"Gas Conversions" section.
IMPORTANT: The gas installation must conform with local
codes, or in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 - latest edition.
The gas supply line shall be equipped with an approved shutoff
valve. This valve should be located in the same area as the
side searing burner and should be in a location that allows ease
of opening and closing. Do not block access to the shutoff valve.
The valve is for turning on or shutting off gas to the side searing
burner.
A.
Gas supply line
Shutoff valve "open" position
B.
C.
To side searing burner
15
B
C