Briggs & Stratton 040248 Manual Del Operario página 15

Ocultar thumbs Ver también para 040248:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Receptacles
CAUTION
See "Don't
Overload
Generator".
Start
generator
and let engine
stabilize
before
connecting
electrical
loads.
Connect
electrical
loads
in OFF position,
then
turn
ON for
operation.
Turn
electrical
loads
OFF and disconnect
from
generator
before
stopping
generator.
120/240
Volt
AC,
30 Amp,
Locking
Receptacle
This receptacle
(Figure
I I) supplies the entire generator
output
and is protected
against overload
by a double-pole
GFCI circuit breal<er.
I
4-Wwe
Cord Set
Y (Hot)
|
X (Hot)
NEMA
LI4-30
/-_
Ground (Green)
Figure I I --
120/240 Volt AC 30 Amp Receptacle
Use a NEMA LI4-30
plug with this receptacle.
Connect
a
4-wwe
cord set rated for 250 Volt AC loads at 30 Amps
(or greater).
You can use the same 4-wwe
cord if you
plan to run a 120 Volt load. Inspect cord set(s)
before
each use. Store
cord set(s) indoors.
When
operating
on LP fuel, this receptacle
powers
120/240 Volt AC, 60 Hz, single phase loads requiring
up
to 7,000 watts of power
(7.0 kW) at 29.16 Amps for
240 Volts or two independent
120 Volt loads at
29.16 Amps each.
120 Volt
A¢,
20 Amp,
Duplex
Receptacles
Each individual duplex receptacle (Figure 12) is protected
against overload by a push-to-reset
circuit breaker. All
four receptacles are also protected
by a double-pole
GFCI
circuit breaker.
Figure 12 --
120 Volt, 20 Amp Duplex Receptacle
Use each receptacle
to operate
120 Volt AC,
single-phase,
60 Hz electrical
loads requiring
up to
2,400 watts (2.4 kW) at 20 Amps of current
when
operating
on LP fuel. Use cord sets that are rated for
125 Volt AC loads at 20 Amps (or greater).
Inspect cord
set(s) before
each use.
[
CAUTION
i
NEVER attempt
to power
a device
requiring
more
amperage
than
generator
or receptacle
can supply.
DO
NOT
overload
the generator.
See "Don't
Overload
Generator".
NOTE:
Follow all safety precautions
when
connecting
any
extension
cord or device to the generator.
Equipment
Ground
The generator
is equipped
with an equipment
grounding
terminal
that connects
the generator
frame components
to the ground
terminals
on the AC output
receptacles.
Ground
the generator
per applicable
codes,
standards,
and
regu lations.
The equipment
ground
is connected
to the AC neutral
wire and the neutral
is bonded
to the generator
frame.
The equipment
grounding
terminal
is shown on
"Generator
Controls
and Features".
Special Requirements
There may be Federal or State Occupational
Safety and
Health Administration
(OSHA)
regulations, local codes, or
ordinances that apply to the intended use of the
generator.
Please consult a qualified electrician,
electrical
inspector, or the local agency having jurisdiction.
In some areas, generators
are required to be
registered
with local utility companies.
If the generator
is used at a construction
site, there
may be additional
regulations which must be
observed.
o
o
m
13