SPECIFICATIONS
Generator
Model 01931-0
Rated Maximum Power (LP*). . . 10.0 kW
Rated Maximum Load Current:
at 240 Volts . . . . . . . . . . . . . . . 41.66 Amps
at 120 Volts . . . . . . . . . . . . . . . 83.33 Amps
Rated AC Voltage . . . . . . . . . . . . 120/240 Volts
Rated Frequency . . . . . . . . . . . . 60 Hz at 3600 rpm
Phase . . . . . . . . . . . . . . . . . . . . . Single Phase
Power Factor . . . . . . . . . . . . . . . 1.0
NG Fuel Supply Pressure. . . . . 5-14 in W.C. (127-356 mm)
LP Fuel Supply Pressure . . . . . . 11-14 in W.C. (279-356 mm)
Normal Operating Range . . . . -20°F (-28.8°C) to 104°F
Output Sound Level . . . . . . . . 70 dB(A) at 23 ft. (7 m) at
Shipping Weight . . . . . . . . . . . . 349 lbs.
Model 01815-0
Rated Maximum Power (LP*). . . 12.0 kW
Rated Maximum Load Current:
at 240 Volts . . . . . . . . . . . . . . . 50 Amps
at 120 Volts . . . . . . . . . . . . . . . 100 Amps
Rated AC Voltage . . . . . . . . . . . . 120/240 Volts
Rated Frequency . . . . . . . . . . . . 60 Hz at 3600 rpm
Phase . . . . . . . . . . . . . . . . . . . . . Single Phase
Power Factor . . . . . . . . . . . . . . . 1.0
NG Fuel Supply Pressure. . . . . 5-14 in W.C. (127-356 mm)
LP Fuel Supply Pressure . . . . . . 11-14 in W.C. (279-356 mm)
Normal Operating Range . . . . -20°F (-28.8°C) to 104°F
Output Sound Level . . . . . . . . 70 dB(A) at 23 ft. (7 m) at
Shipping Weight . . . . . . . . . . . . 349 lbs.
* Natural gas rating will depend on specific fuel but typical
derates are between 10 to 20% off the LP gas rating.
NOTE: If operating the generator under freezing
temperatures (32°F), purchase an optional cold weather
package from your local servicing dealer.
Briggs & Stratton Power Products Home Generator
Owners Manual
(40°C)
full load
(40°C)
full load
FAULT DETECTION
SYSTEM
The generator may have to run for long periods of time
with no operator present. For that reason, the system is
equipped with sensors that automatically shut down the
generator in the event of potentially damaging conditions,
such as low oil pressure, high oil temperature, over speed,
and other conditions.
A light on the generator's control panel is called the
Diagnostic LED. A similar LED indicator is installed at a
convenient inside location. Both LED's will turn on and off
in the same series of blinks if certain problems are
detected in your HSG.The blink pattern is repeated with a
brief pause between each series.The number of blinks in
the series indicates the detected fault, as listed near the
control panel, on the mounting plate and as follows:
Number of LED Flashes
1
2
3
4
5
6
7
Reset Fault Detection System
The operator must reset the fault detection system each
time it activates.To do so, place the AUTO/OFF/MANUAL
switch in the OFF position for 30 seconds or more.
Return the Home Standby Generator to service after
correcting the problem by placing the
AUTO/OFF/MANUAL switch in the AUTO position.
A description of each fault and suggested remedies are as
follows:
No LED - Discharged Battery
This condition is caused by a completely discharged
battery.To remedy the problem, remove the 15 Amp fuse
and disconnect the battery from the generator.Take the
battery to a local battery store for analysis.
Replace the battery after it has been fully recharged,
connecting the NEGATIVE cable last. Install the 15 Amp
fuse.
14
Fault Description
Low battery voltage
Low oil pressure
Low voltage
Engine fail to start
Low frequency
Engine overspeed
Oil temperature high