Putting Into Service; Air Supply; Operating Procedure - avdel Genesis G2LB Manual De Instrucciones

Ferramenta mecanica hidro-pneumatica
Ocultar thumbs Ver también para Genesis G2LB:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

P u t t i n g i n t o S e r v i c e
A i r S u p p l y
All tools are operated with compressed air at an optimum pressure of 5.5 bar. We recommend the use of pressure regulators and
automatic filtering systems on the main air supply. These should be fitted within 3 metres of the tool (see diagram below) to ensure
maximum tool life and minimum tool maintenance.
Air supply hoses should have a minimum working effective pressure rating of 150% of the maximum pressure produced in the system or
10 bar, whichever is the highest. Air hoses should be oil resistant, have an abrasion resistant exterior and should be armoured where
operating conditions may result in hoses being damaged. All air hoses MUST have a minimum bore diameter of 6.4 millimetres or
Read daily servicing details page 12.
O p e r a t i n g P ro c e d u r e
Ensure that the correct nose assembly is fitted.
Connect the tool to the air supply.
Disable the vacuum extraction system by turning Rotary Valve
65 until you feel or hear no air flow out of the front of the
nose assembly.
Push the fastener stem through the application hole.
Place the collar on the stem (orientation as shown).
Keeping the head of the stem against the application, push
the tool onto the protruding stem.
Fully depress the trigger. One cycle will ensure that the collar
is swaged into the lock grooves of the stem and that the
stem breaks at the breaker groove.
The tool completes its cycle by pushing itself off the collar
and the spent stem will be pushed to the rear of the tool on
insertion of the next fastener.
Item numbers in bold refer to the General Assembly drawing and Parts List on pages 16-17.
STOP COCK
(USED DURING MAINTENANCE
OF FILTER/REGULATOR)
3 METRES MAXIMUM
8
PRESSURE REGULATOR
AND FILTER (DRAIN DAILY)
®
Placing AVDELOK
/MAXLOK
1
/
inch.
4
TAKE OFF POINT
FROM
MAIN SUPPLY
MAIN SUPPLY
DRAIN POINT
®
7

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido