N o s e A s s e m b l i e s
F i t t i n g I n s t r u c t i o n s A v d e l o k
Air supply must be disconnected when fitting or removing nose assemblies
•
Assemble Chuck Jaws 6, Spring Guides 7 and Spring 8 into Chuck Collet 5. (Lightly coat Chuck Jaws and Chuck Collet internal
bores with Molylithium grease).
•
Screw chuck collet (assembled as above) onto Chuck Collet Adaptor of tool assembly (item 1 page 16). Lock in position with
Friction Ring 9.
•
Screw Anvil 3 into front of placing tool.
•
Assemble Buffer 2 over Anvil 3 followed by Anvil Casing 1.
•
Fit rubber Shroud 4 over Anvil Casing 1 and Buffer 2 and locate over flange of Anvil 3 to hold components in position.
4
S e r v i c i n g I n s t r u c t i o n s
•
Remove nose assembly from tool using the reverse procedure to the fitting instructions above.
•
Clean parts. Worn or damaged parts should be replaced.
•
Check Anvil 3 for wear and/or damage to the swaging bore.
•
Lightly coat Chuck Jaws 6 and Chuck Collet 5 internal bores with Molylithium grease.
•
Assemble as above instructions.
•
For ease of fitting the rubber shroud, liquid soap can be smeared on its internal surface prior to assembly.
Item numbers in bold refer to the Avdelok
®
I M P O R T A N T
9
7
8
3
®
Nose Assembly on page 8.
7
6
5
1
2
1
9