STORAGE
If you store the pneumatic tool for an extend-
ed period of time, you should lubricate abun-
dantly (3 to 4 caps of oil). Place oil and run the
machine for a few seconds to distribute the
lubricant. Store in a clean, dry place.
The parts shown in the assembly for proper
operation of your air tools are identified as
follows:
1. Air filter.
2. Regulator.
3. Lubricator.
4. Emergency shut-off valve.
5. Hose diameter.
6. Thread size.
7. Coupling.
8. Safety Air Fuse.
9. Oil.
10. Grease (During assembly).
TECHNICAL DATA
SQUARE DRIVE
FREE SPEED
MAX. TORQUE
AIR CONSUMPTION
AIR INLET
SOUND PRESSURE
VIBRATION
WEIGHT
48h
90 psi
E N G L I S H •
1" (25,4 mm)
3 000 r/min
2 500 lbf-ft (3 389 Nm)
14,5 CFM (410 L/min)
1/2" NPT
87 dBA
1,7 m/s²
16,8 kg (37 lb)
U se r's m a n ua l
24h
7