Introduction
The 4iE thermostat is designed to aid in the comfort of your home by providing timed regulation of your heating system. The thermostat is designed to receive temperature input
signals from the following sensors:
1.
Air sensor located inside thermostat
2.
Floor sensor installed in floor if using underfloor heating (see Warmup heater instructions for details)
3.
Optional 2nd sensor
The thermostat is not a safety device. In order to avoid damaging your system the correct system and floor type should be selected during the thermostat programming process.
Electrical Specification:
•
Supply voltage: 230V +/-15% at 50Hz
•
Thermostat is not designed for use with intermittent power supply.
•
Maximum Switch Load: 16A resistive
•
Insulation Class : II
•
Housing : IP33
•
Standards: EN60730-1 & EN60730-2-9 standards
WARNING – Important safety note
This product uses mains voltage electricity and work should only be carried out by a qualified electrician. You should always isolate the power supply before attempting to install
or repair the 4iE thermostat. The thermostat should not be put into operation unless you are certain that the entire heating installation complies with current general safety
requirements for electrical installations. Electrical installation to be in accordance with latest IEE Wiring Regulations and appropriate Statutory Regulations.
Location
The thermostat should be installed inside a single gang electrical wall box that is at least 30mm deep. For optimal performance the thermostat should be located in an area with
good ventilation. It should not be beside a drafty window/ door, in direct sunlight or above another heat generating device (e.g. radiator or TV).
The thermostat is designed for operation between 0°C and 55°C with relative humidity less than 80%.
Connect to MyWarmup
Once your 4iE is powered up, you need to create your MyWarmup account. Navigate your web browser to
Enter your email address and create a password for your account. You will be sent a confirmation email when your account is set up. Make sure you check your spam folder as
well as your inbox.
When you've received your account activation email, you can connect your 4iE to the account. Ensure your 4iE is connected to the internet. If you see an error icon on the
homescreen like below, then your thermostat is not connected to the internet. If you can't connect to the internet, you can skip this stage and connect any time in the future.
Not connected to Server
When your 4iE is connected to the internet, just enter the unique code displayed on the connection screen into MyWarmup. Your 4iE will then be connected.
4
No WiFi Connection
my.warmup.com
If you see these icons, call Warmup for 24/7/365 assistance on 0845 345
2288