5
Using the RAID Mode
The device is factory preset to JBOD mode (system will recognize the two drives as
two individual volumes). If you wish to only change the RAID mode, please skip step
1 and go directly to step 2. Verify the device is powered on while changing the RAID
mode.
1. Insert two hard drives into the enclosure, plug in the USB 3.0 cable, connect the
power adapter to the enclosure, and then turn on the power. The RAID mode is
set default to JBOD.
2. Select the preferred RAID mode by using the RAID switch located on the back of
the enclosure.
3. Press the "Reset" button located on the back of the device for at least 3 seconds
until the front white LED indicator flashes then release. The white LED indicator
will become solid white once the RAID mode change has been completed.
4. Reformatting the hard drive(s): delete the old drive partition(s) (if applicable)
and recreate new drive partition(s).
Caution: Changing RAID settings permanently erase any erase data on the hard drive
and cannot be restored. If there are existing data on the hard drive, please
back up the data first then setup the RAID.
6

LED Status Indicators

Front Panel LEDs
Back Panel LED
4
RAID Status
Empty Bay
HDD(s) in Bay
HDD Access
HDD Fail
Verifying or Confirmation
RAID Rebuilding
RAID Rebuild Completed
LED Indicators
No light
Solid white LED
Flashing white LED
Solid red LED
Flashing white LED
Flashing white LED
No Light